Technical Data; Power Requirements - Truper CAZ-EL-7B Manual Del Usuario

Cortador de azulejos eléctrico
Ocultar thumbs Ver también para CAZ-EL-7B:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Technical Data

Code
Description
Voltage
Frequency
Current
Power
Speed
Work Cycle
Conductors
Insulation quality
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
WARNING

Power Requirements

WARNING
To prevent electric shock, the tool shall be grounded while
in use. • Connect the plug into a correctly grounded outlet as shown in
example A. Not all the outlets are properly grounded. If in doubt, verify with a
qualified electrician. • If the outlet where you will connect the tool has two
poles (2 orifices). UNDER ANY CIRCUMSTANCE, DO NOT REMOVE OR
ALTER THE PLUG'S GROUND CONNECTOR. Use a temporary adaptor as
shown in example B and always connect the ground conductor lug as shown.
CAUTION
When using an extension cable, verify the gauge is enough
for the power that the tool needs. A lower gauge cable will cause voltage drop
in the line, resulting in power loss and the motor will overheat. The following table shows the right size to use depending on cable's
length and the ampere capability shown in the tool's nameplate. When in doubt use the next higher gauge.
Ampere
Capacity
From 0 and up to 10 A
From 10 and up to 13 A
From 13 and up to 15 A
From 15 and up to 20 A
WARNING
When using power tools outdoors use a
Use". These extension cables are specially manufactured for outdoors use and reduce the risk of electric shock.
WARNING
All the cabling, power connections and the ground connection of the system shall
comply with the OFFICIAL MEXICAN STANDARD NOM - 001 SEDE-2012, INSTALACIONES ELÉCTRICAS
(UTILIZATION) or with the local codes or regulations. Use the services of a qualified electrician.
Disc
50 minutes' work per 20 minutes' rest. Maximum 6 hours daily
Number of
Conductors
3 (one grounded)
CAZ-EL-7B
16539
Wet Tile Saw
Diamond | Diameter: 7"
With: 5/64" | Arbor: 7/8"
120 V
60 Hz
4,8 A
3/4 HP
3 500 RPM
18 AWG X 3C with insulation temperature 221 °F
Class I
Power cord grips type: Y
Build quality: Basic Insulating.
Thermal insulation on motor winding: Class F
Extension Gauge
From 6 ft to 49 ft
18 AWG
16 AWG
14 AWG
8 AWG
grounded extension cable labeled "Outdoors
Authorized Service Center.
A
B
CAUTION
|
Higher than 49 ft
16 AWG
14 AWG
12 AWG
6 AWG
ENGLISH
3