Technical Data; Power Requirements - Truper SINCO-10X2 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Technical Data

Code
Description
Disc
Shaft diameter
Voltage
Current
Power
Speed
Duty cycle
Conductors
Insulating
Table angles
Cutter head angles
WARNING
make it replaced by the manufacturer or in a
Power insulation in this tool is affected by liquid spills or splashing while operating.
Do not expose to rain, liquids and / or humidity.
WARNING

Power Requirements

WARNING
Tools with double insulation and reinforced insulation are
equipped with a polarized plug (one prong is wider than the other). This plug will
only fit in the right way into a polarized outlet. If the plug cannot be introduced into
the outlet, reverse the plug. If it still doesn't fit, call a qualified electrician to install
for you a polarized outlet. Do not alter the plug in any way. Both insulation types
eliminate the need of both a grounded third power cord with three prongs or a
grounded power connection.
WARNING
When using an extension cable, verify the gauge is enough for
the power that your product needs. A lower gauge cable will cause voltage drop in the line, resulting in power loss and
overheating. The following table shows the right size to use depending on cable's length and the ampere capability shown in
the tool's nameplate. When in doubt use the next higher gauge.
Ampere
Capacity
from 0 A and up to 10 A
from 10 A and up to 13 A
from 13 A and up to 15 A
from 15 A and up to 20 A
WARNING
When operating power tools outdoors, use a
extension cable labeled "For Outdoors Use". These extensions are specially designed for
operating outdoors and reduce the risk of electric shock.
127 V
50 minutes work and 20 minutes idle. Maximum 6 hours per day.
14 AWG x 2C with insulating temperature of 221 °F
Power cord grips used in this product: Type "Y"
Thermal insulation on motor winding: Class B
To prevent power discharge or serious accident if the power cable gets damaged
Before gaining access to terminals, all power circuits should be disconnected.
Number of
Conductors
3 (one grounded)
* It is safe to use only if the extensions have a built-in artifact for over current protection.
AWG = American Wire Gauge. Reference: NMX-J-195-ANCE
SINCO-10X2
16869
Slide compound miter saw
10" with 40 teeth
5/8"
Frequency
15 A
2
1
/
Hp
2
5 000 RPM
Class II
0° / ±15°/ ± 22.5° / ± 31.6 °/ ± 45°
0° / 15° / 30° /45°
Build quality: Reinforced insulation
Authorized Service Center.
Extension gauge
from 5.9' to 49.2' |
18 AWG( * )
16 AWG
14 AWG
8 AWG
grounded
60 Hz
higher than 49.2'
16 AWG
14 AWG
12 AWG
6 AWG
ENGLISH
3

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

16869

Tabla de contenido