Technical Data

Code
Description
Disc
Shaft diameter
Voltage
Current
Power
Speed
Duty cycle
Conductors
Insulating
Table angles
Cutter head angles
WARNING
make it replaced by the manufacturer or in a
Power insulation in this tool is affected by liquid spills or splashing while operating.
Do not expose to rain, liquids and / or humidity.
WARNING

Power Requirements

WARNING
The tool shall be grounded while in use to prevent an electric shock.
• Connect the plug into a correctly grounded power outlet, as shown in Figure A.
Not all the power outlets are correctly grounded. If you do not know for sure
verify with a qualified electrician.
• If the plug destined for the tool is a two-prong (two orifices), FOR NOT
REASON AT ALL REMOVE OR ALTER THE GROUND CONDUCTOR SET IN THE
PLUG. Use a temporary adapter as shown in Figure B and always connect the
ground ring as indicated.
CAUTION
When using an extension cable, verify the gauge is enough
for the power that your product needs. A lower gauge cable will cause voltage
drop in the line, resulting in power loss and overheating. The following table
shows the right size to use depending on cable's length and the ampere
capability shown in the tool's nameplate. When in doubt use the next higher
gauge.
Ampere
Capacity
from 0 A and up to 10 A
from 10 A and up to 13 A
from 13 A and up to 15 A
from 15 A and up to 20 A
* It is safe to use only if the extensions have a built-in artifact for over current protection.
WARNING
When operating power tools outdoors, use a
extension cable labeled "For Outdoors Use". These extensions are specially designed for
operating outdoors and reduce the risk of electric shock.
127 V
50 minutes work and 20 minutes idle. Maximum 6 hours per day.
14 AWG x 3C with insulating temperature of 221°F
Class I
Power cord grips used in this product: Type "Y"
Thermal insulation on motor winding: Class F
To prevent power discharge or serious accident if the power cable gets damaged
Before gaining access to terminals, all power circuits should be disconnected.
Number of
Conductors
3 (one grounded)
AWG = American Wire Gauge. Reference: NMX-J-195-ANCE-2006
SINA-10
12462
Compound miter saw
10" with 80 teeth
5/8"
Frequency
15 A
2 1/2 Hp
5 500 RPM
IP grade
From 0° to ± 45°
From 0° to 45°
Build quality: Supplementary
Authorized Service Center.
CAUTION
Extension gauge
from 5.9' to 49.2' |
18 AWG( * )
16 AWG
14 AWG
8 AWG
grounded
60 Hz
IP20
A
B
higher than 49.2'
16 AWG
14 AWG
12 AWG
6 AWG
ENGLISH
3