Descargar Imprimir esta página

jbc CD-BE Manual De Instrucciones página 7

Ocultar thumbs Ver también para CD-BE:

Publicidad

Idiomas disponibles

Idiomas disponibles

Parameters
Should you wish to modify the locked parameters (
www.jbctools.com/en/form and JBC will contact you. Be careful when using these parameters
as they may reduce the tip life if not used properly. Please follow the recommended guidelines:
Station Settings
Recommendations
Parameter description
Temperature unit
N/a
Celsius (ºC) or Fahrenheit (ºF)
Maximum temperature
Set the maximum
temperature to work
with.
Max. temp by default is
400°C (750°F). This is
The station temperature
considered high enough
range is 90-450ºC
to work with most lead-
(190-840ºF). Change the
free applications.
temperature limits when
working with less common
Minimum temperature
applications such as low /
Set the minimum
high melting point solde-
temperature to work
ring (HMP) or plastics (e. g.
with.
riveting).
Min. temp. by default is
200ºC (392ºF). This
is considered to be a
proper starting point for
leaded applications.
Metronome
Useful for setting a work rate
This activates a beep sound.
in repetitive jobs. The beep
Frequencies vary from 1 to 50
lets you know the length of
seconds.
time the tip must be in con-
tact with the soldering joint.
Help text
N/a
Activate this parameter to
receive info from the system.
Beep
N/a
enable/disable the beep
sound of the keypad.
Change pin
The PIN must be entered
Change the default security
every time a parameter is
PIN number (0105).
changed.
12
), please fill in the form on
Warnings
In most cases,
working with temperatures
over 400°C (750°F) can
damage the PCB and its
components. even in short
time periods of tip contact
with the soldering joint, the
flux may not work properly
and could seriously reduce
tip life.
If the solder joint requires
more power (e.g. multila-
yered or high dissipation
boards), JBC strongly
recommends using other
aids like preheaters.
N/a
N/a
N/a
N/a
Tool Settings
Parameter description
Recommendations
Fix one temperature
Ideal for soldering more than
Fix a value within the
one component at a specific
temperature range of the sta-
temperature. The station will
tion (90-450ºC/190-840ºF).
reject any attempt to change
the temperature.
This allows a quick change
Temperature levels set
Similar to "Fix one temp"
between 3 different tempe-
parameter. In this case, the
ratures. Set them according
user can set up to 3 values for
to the allowed values for your
different power requirements.
soldering applications.
Sleep delay
Because our tools reach the
Set the time that the tool
working temperature from the
will remain at the selected
deafult Sleep mode in only a
temperature when in the
few seconds, this parameter
stand before entering
is preset to 0 min. Once the
sleep mode. The tip tem-
tool is returned to the stand
perature will then drop to
the temperature will automati-
the Sleep temperature.
cally drop to the sleep tempe-
rature, extending tip life and
avoiding oxidation. Retinning
the tip before placing the tool
in the stand will protect the tip
and extend its life.
Sleep temperature
The sleep temperatures
This is the set tempera-
are set to achieve a ba-
ture the tip reaches when
lance between preventing
returned to the stand.
oxidation and reaching the
working temperature in a few
seconds.
w w w.jbctools.com
Warnings
N/a
N/a
Setting these
parameters to higher
values will unnecessarily
accelerate oxidation
and shorten tip life
especially when working
with temperatures up to
450°C (840°F).
13

Publicidad

loading