Descargar Imprimir esta página

jbc CD-BE Manual De Instrucciones página 8

Ocultar thumbs Ver también para CD-BE:

Publicidad

Idiomas disponibles

Idiomas disponibles

Tool Settings
Parameter description
Recommendations
This function completely
Hibernation Delay
Set the time the tool will
protects the tip from oxida-
remain at Sleep tempe-
tion during long periods of
rature before entering
inactivity while the tool is in
the Hibernation mode.
the stand.
At this time, the power
Retinning the tip before pla-
supply is cut off and
cing the tool in the stand also
the tip remains at room
helps prevent oxidation and
temperature.
extends the life of the tip.
Temp Adjustment
Set values within ±50°C
It provides a more preci-
(± 90°F) to achieve zero error.
se adjustment between
JBC strongly recommends
the selected temperature
the use of TID-A or TIA-A
and the actual one.
Thermometers to obtain
precise readings.
14
Warnings
Increasing the default
value will accelerate oxi-
dation and shorten the tip
life.
When the user chan-
ges the cartridge type, the
parameter should be reset to
0°C/F or to the value needed
for this cartridge. e.g. If a
correction of +20°C (+36°F)
is set for the C245966 (thick
type) and then the user
changes the cartridge for a
C245030 (which is thinner)
without resetting, they would
be working at a temperature
of +20°C (+36°F) lower for
the C245030 which does
not need any temperature
adjustment.
Maintenance
Before carrying out maintenance, always allow the equipment to cool.
- Clean the station screen with a glass cleaner
or a damp cloth.
- Use a damp cloth to clean the casing and
the tool. Alcohol can only be used to clean
the metal parts.
- Periodically check that the metal parts of
the tool and stand are clean so that the
station can detect the tool status.
- Maintain tip surface clean and tinned prior
to storage in order to avoid tip oxidation.
Rusty and dirty surfaces reduce heat
transfer to the solder joint.
- Periodically check all cables and tubes.
- Replace a blown fuse as follows:
1. Pull off the fuse holder and remove the
fuse. If necessary use a tool to lever it off.
- Replace any defective or damaged pieces. Use original JBC spare parts only.
- Repairs should only be performed by a JBC authorized technical service.
w w w.jbctools.com
Clean
periodically
2. Press the new fuse into the fuse holder
and replace it in the station.
15

Publicidad

loading