Installation Instructions - Nordcap HHT 081 E Manual Del Usuario

Ocultar thumbs Ver también para HHT 081 E:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

INSTALLATION INSTRUCTIONS

INSTRUCTIONS FOR POSITIONING
If the walls next to the appliance are of inflammable material, they should be suitably clad.
Fire prevention regulations must be scrupulously observed.
The electric wiring must never be under strain. Do not obstruct the suction inlets or heat dispersion outlets; scrupulously
follow the installation diagrams.
Remove the protective film.
INSTRUCTIONS FOR ELECTRICAL CONNECTION AND EQUIPOTENTIAL SYSTEM
The electrical safety of this appliance is guaranteed only if it is connected correctly to an efficient earthing system, in accordance
with current safety regulations. The manufacturer shall not be responsible for any damage caused by failure to earth the installation
properly.
The appliance must also be included in a equipotential system. Make the connection through the terminal situated on the rear of
the appliance, and marked by the relevant symbol, according to current safety regulations.
In case of replacement of the power cord, the length of the wires between the connection point of the cable and the terminals must
allow the active conductors to be tightened before being earthed.
SAFETY AND CONTROL SYSTEMS
Auxiliary circuit switch
Restoring the safety thermostat If during machine use, this should switch off due to the safety thermostat intervening, you can
Fuses positioned next to the terminal board protect the electric circuit
reset it. The position of the safety thermostat that is to be reset is indicated on the rear of the
machine. Unscrew the screw to access the reset button of the thermostat inside the machine.
Use the tip of a tool to enter the reset hole and push slightly. Then tighten the screw again.
18
GB
Ed. 0117

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

437031081