Mount the Light Control
1. Place the mounting bolt through the front of the
junction box cover. Push the small gasket hole over
the mounting bolt.
2. Make sure the wire connectors and wires are inside
the junction box. Align the mounting bolt with the
center hole in the mounting strap.Secure the fixture
to the mounting strap.
3. Push the rubber plug firmly into place.
4. If not installed on a weatherproof box, caulk the
wall plate and mounting surface with silicone.
5. Adjust the lamp holders by loosening the lock nuts
but do not rotate the lamp holders more than 180°
from the factory setting.
Mounting Bolt
Rubber Plug
Push the rubber plug
over the mounting bolt.
Keep lamps at least
1" (2.5 cm) from the
sensor.
TEST AND ADJUSTMENT
1. Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1
before it will detect motion. When first turned
on, wait 1
/
1
2
2. Turn the SENSITIVITY (SENS) control to the
minimum position (MIN) and the ON-TIME control
to the TEST position.
ON-TIME
10 5 1 TEST
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
8 ft.
(2.4 m)
Maximum Range
NOTE: If fixture is mounted higher than 8 ft.(2.4 m), aiming
the sensor down will reduce coverage distance.
4
/
minute warm up period
1
2
minutes.
SENS
MIN
60 ft.
(18.3 m)
Maximum
Coverage Angle