8.1 - POWER ADJUSTMENT
This rapid configuration menu option allows the motor power to
be adjusted. The value displayed is the value currently set. Using
h
i
the
and
keys, select the value to be set and press OK to
confirm and continue.
30
100
÷
Values from 30 (minimum) to 100 (maximum).
Equal values for both motors
PErS
Customised configuration: if the display shows
PErS
, this means the two motors have different
power values set using the
options in the control unit programming menu.
PErS
Selecting the
maintaining the previously set values.
8.2 - OBSTACLE SENSOR ADJUSTMENT
The PD12 control unit has a sophisticated system allowing
detection of whether gate movement is impeded by an obstacle.
This system is based on measurement of the current absorbed by
the motor: an unexpected increase in current absorption indicates
the presence of an obstacle. the obstacle sensor is also used to
recognise the arrest points.
Detection of an obstacle during normal movement of the gate
results in brief inversion of motion in order to free the obstacle.
The gate is stopped when one of the following conditions is
present:
-
During slowing
-
During the first work cycle after accessing the programming
menu
-
After having powered-up the control unit
This menu option is used to adjust the motor current value that
trips the obstacle sensor.
The value displayed is the value currently set. Using the
i
keys, select the value to be set and press OK to confirm and
continue.
The possible options are:
1.0
3.5
÷
Values from 1.0 to 3.5 Amperes: values common to
both motors. The minimum value corresponds to
maximum obstacle sensor sensitivity, and vice-versa.
Based on the value selected, the control unit also
calculates the acceleration and deceleration rate and
the start thrust function.
Pot1
Pot2
and
options exits the menu,
h
and
Pot.
PErS
Customised configuration: if the display shows
PErS
, this means the two motors have different
values set using the
the control unit programming menu.
Selecting the
maintaining the previously set values.
Please note: if time self-training has been performed during
initialisation, the control unit has also performed automatic
strain recognition and has automatically set the sensitivity
value.
If, on the other hand, self-training has not been performed,
the pre-set value is the default.
SEnS
- 53 -
100
60
30
PErS
SEn1
SEn2
and
options in
PErS
options exits the menu,
3.5A
3.0A
1.0A
PErS