Bosch MTS 6516 VCI Manual Original página 24

Módulo para el diagnóstico de la unidad de control
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47
en
24 | MTS 6516 VCI |
You are prompted to respond if you are sure you
wish to cancel the installation.]
4. The InstallShield wizard displays the Configure
USB panel. You are instructed to power on the VCI
and connect it to the PC using the USB cable. Click
Configure.
5. Click Finish to complete the installation. The Ins-
tallShield Wizard places the VCI Manager icon on
your desktop.
5.2
Setting Up the VCI Hardware
Your first connection is to the PC where you have in-
stalled VCI Manager software. You will need the USB
cable to configure your VCI using VCI Manager.
5.2.1
Identifying Your VCI
The VCI label is located on the back of the VCI. The VCI
identification number has two parts: a manufacturing
code for traceability and a unique serial number. The
serial number is used to identify the VCI in the VCI
Manager software. You will need to refer to this serial
number when you are using VCI Manager to configure
the VCI and perform software updates.
5.2.2
Updating the VCI Software
The MTS 6512 VCI is shipped from the factory with a
base version of firmware. Before operating your VCI we
recommend visiting the following Bosch Diagnostics
OES website to see if a newer version of the VCI firm-
ware is available for your VCI.
http://www.diagnostics-oes.de/diagnostics_oes/en/service/down-
loads.htm
Use the following procedure to update the firmware on
your VCI.
1. Select the VCI Manager icon from the PC Desktop.
Before proceeding to the next step, make sure your
VCI is powered on and the VCI is connected to the
PC using the USB cable.
2. Select the Update VCI button to start the update
process. [Note, at this time, you are only able to
update your VCI using the USB connection. Wi-Fi
firmware updates are not enabled.]
|
1699200075 B
2017-06-20
3. Verify VCI Serial Number and the firmware version
information is correct.
4. Select the Start Update button.
5. Do not unplug the VCI from the PC or remove power
from the VCI during the update process. Select OK
to continue.
6. The update process will take about 12 minutes to
complete. Once the update process is complete the
VCI will automatically reboot. Wait until you hear the
beep from on the VCI before proceeding to use your
VCI.
5.2.3
Configuring the VCI Using VCI Manager
In order to configure a VCI to communicate on your
network you must connect the VCI, via USB, to a PC
running VCI Manager software. Use the following steps
to configure your VCI.
1. Double-click the VCI Manager icon on your desktop
to launch the VCI Manager software.
2. In the VCI Manager software VCI Explorer tab, select
the VCI in the Detected VCIs window. Click the Show
Details button to see details about the selected VCI.
3. Click the Connect button to connect to the selec-
ted VCI over USB. The VCI is displayed with a green
check mark on your display indicating that your VCI
Manager software is in control of that VCI. Note: If
your VCI is connected to another networked PC, it
will still be detected by the VCI Manager but will be
displayed with a red symbol indicating that it is not
available. [If your VCI is connected via USB to your
computer, the VCI Manager functions on all tabs
are available; if your VCI is not connected via USB,
the functions on the Network Setup and VCI Update
tabs are not available.]
5.2.4
Check PC and VCI Software Versions
Typically, the VCI Manager software installed on your
PC and the software installed on the VCI must have
matching versions in order for the VCI to operate pro-
perly. Use the following steps to check your software
versions.
1. Connect the VCI to your computer via USB cable.
2. Double-click the VCI Manager icon on your desktop
to launch the VCI Manager software.
3. On the VCI Explorer tab, select your VCI in the De-
tected VCIs window.
Robert Bosch GmbH