Descargar Imprimir esta página

Vimar ELVOX K40540.E Manual Del Instalador página 15

Publicidad

K40540.E - K40540.E2 - K40542.E - K40542.E2
a - Connection terminal block
Terminals
Description
1, 2
Due Fili Plus Bus
FP
"Local Landing Call" input (reference to
terminal M).
M
Earth reference.
12V
12V (50 mA max): call repetition power
supply.
CH
"Call repetition" output (open-collector, 24
V max)
N.B.: the maximum connection distance to the
terminals , except for the Due Fili Plus Bus, is 10m.
Note: the functions associated with the LC "Local Landing Call" input and the CH Open
Collector output can be modified via programming. For the functions which can be
activated, please refer to the configuration software use and configuration manual.
a1 - Contact connection terminals (N.O. by default/N.C.
configurable with the configuration software) for Alert
function (only for 40542); reconfigurable to activate the
"professional firm" function (only N.O.)
a - Bornier de connexion
Bornes
Description
1, 2
Bus Due Fili Plus
FP
Entrée « Appel palier local (reliée à la borne
M).
M
Référence de masse.
12V
12V (50 mA maxi) : alimentation répétition
d'appel.
CH
Sortie (open-collector, 24 V maxi) « Répétition
d'appel »
Remarque : la distance maximale des connexions aux
bornes, à l'exception du Bus Due Fili Plus, correspond
à 10m.
Remarque : les fonctions associées à l' e ntrée Palier « Appel Palier local » et à la sortie
Open Collector CH peuvent être modifiées à travers une programmation. Pour les
fonctions activables, consulter le manuel d'utilisation et de configuration et utiliser le
logiciel de configuration.
a1 - Bornes de connexion contact (NO par défaut/NF
configurable avec logiciel) pour fonction Alerte (uniquement
pour 40542) ; reconfigurable pour l'activation de la fonction «
bureau/cabinet professionnel » (uniquement NO)
a - Anschlussklemmenleiste
Klemmen
Beschreibung
1, 2
Bus Due Fili Plus
FP
Eingang "lokaler Etagenruf" (Signal an
Klemme M).
M
Massesignal.
12V
12V (50 mA max.): Versorgung
Rufwiederholung.
CH
Ausgang (Open-Collector, 24 V max.)
"Rufwiederholung"
Hinweis: Die maximale Anschlusslänge an die
Klemmen, den Bus Due Fili Plus ausgenommen, beträgt
10m.
Hinweis: Die mit Eingang FP "lokaler Etagenruf" und Open Collector-Ausgang CH
verknüpften Funktionen können mittels Programmierung geändert werden. Für die
aktivierbaren Funktionen wird auf die Bedienungs- und Konfigurationsanleitung und
die Konfigurationssoftware verwiesen.
a1 - Kontakt-Anschlussklemmen (NO standardmäßig/NC mit
Konfigurationssoftware konfigurierbar) für die Funktion
Warnmeldung(nur 40542); zur Aktivierung der Funktion
b - Due Fili Plus bus termination (ABC jumper)
SWITCH TABLE
A = The BUS cable enters terminals 1, 2 and continues
to another indoor station
B = The BUS cable with a characteristic impedance of
100 Ohms (Elvox 732I or 732H cable) enters terminals
1, 2 and the riser stops in the indoor station
C = The BUS cable with characteristic impedance of
50 Ohms (Cat. 5 or Cat. 6 twisted pair cable) enters
terminals 1, 2 and the riser stops in the indoor station
c - Talk volume control in the handset:
- Standard Volume (Default): Jumper inserted
- Volume increased: Jumper not inserted
d - "Config" button: for Dip switch configuration mode
e - Configuration Dip switch
f - Pre-arranged for through holes for connecting the raceway
to the wall.
b - Terminaison Bus Due Fili Plus (Jumper ABC)
TABLEAU SWITCH
A = Le câble du BUS arrive aux bornes 1, 2 puis se
dirige vers un autre poste intérieur
B = Le câble BUS avec une impédance caractéristique
de 100 ohms (câble Elvox 732I ou 732H) arrive aux
bornes 1, 2 et la colonne montante s'arrête au poste
intérieur
C = Le câble BUS avec une impédance caractéristique
de 50 ohms (câble cat. 5 ou cat. 6 à paires torsadées)
arrive aux bornes 1, 2 et la colonne montante s'arrête
au poste intérieur
c - Réglage du volume de conversation dans le combiné :
- Volume Standard (par défaut) : Jumper inséré
- Volume augmenté : Jumper non inséré
d - Touche « Config » : pour la modalité de configuration via Dip-
switch
e - Dip-switch de configuration
f - Prédispositions, permet de créer éventuellement des orifices
pour le passage des connexions de la gaine en saillie.
"professionelles Büro" neu konfigurierbar (nur NO)
b - Bus-Abschluss Due Fili Plus (Jumper ABC)
SCHALTERTABELLE
A = Das BUS-Kabel tritt in die Klemmen 1, 2 ein und
führt zu einer anderen Innenstelle
B = Das BUS-Kabel mit typischer Impedanz 100 Ohm
(Elvox Kabel 732I oder 732H) tritt in die Klemmen 1, 2
ein und die Steigleitung endet an der Innenstelle
C = Das BUS-Kabel mit typischer Impedanz 50 Ohm
(Kabel Cat.5 oder Cat.6 mit gepaarten Doppeladern)
tritt in die Klemmen 1, 2 ein und die Steigleitung
endet an der Innenstelle
c - Einstellung der Gesprächslautstärke im Hörer:
- Standardlautstärke (Werkseinstellung): Jumper eingesetzt
- Höhere Lautstärke: Jumper nicht eingesetzt
d - Taste "Konfig": zur Konfiguration mittels Dip-Schalter
e - Dip-Schalter für Konfiguration
f - Vorbereitungen, zur Anfertigung etwaiger Anschluss-
Durchgangsbohrungen von Kanal zur Wand.
15

Publicidad

loading

Este manual también es adecuado para:

Elvox k40540.e2Elvox k40542.eElvox k40542.e2