CHECK FOR GAS LEAKS
WARNING: The gas connections of your Summit
have been factory tested. We do however recommend that
you leak check all gas connections before operating your
®
Summit
gas grill.
REMOVE CONTROL PANEL
Tool required: Phillips Screwdriver.
1)
Remove the burner control knobs.
2)
Remove the two screws that secure the control panel to the frame.
3)
Remove the control panel. Tilt panel forward and lift up and away from grill.
Completely remove the control panel (3) from the cooking box assembly exposing the
valves, burners, igniter, and manifold.
CHECK FOR GAS LEAKS
Do not use an open flame to check for gas leaks. Be sure
there are no sparks or open flames in the area while you
check for leaks. Sparks or open flames will result in a fire or
explosion, which can cause serious bodily injury or death
and damage to property.
WARNING: You should check for gas leaks every time you
disconnect and reconnect a gas fitting.
Note: All factory-made connections have been thoroughly checked for gas leaks. The
burners have been flame-tested. As a safety precaution however, you should recheck
all fittings for leaks before using your Weber
may loosen or damage a gas fitting.
WWW.WEBER.COM
®
GAS INSTRUCTIONS
®
gas grill
DANGER
®
Gas Barbecue. Shipping and handling
WARNING: Perform these leak checks even if your
barbecue was dealer or store assembled.
You will need: a soap and water solution, and a rag or brush to apply it.
Note: Since some leak test solutions, including soap and water, may be slightly
corrosive, all connections should be rinsed with water after checking for leaks.
If your grill has a side burner make sure the side burner is off.
To perform leak checks: open cylinder valve by turning the cylinder valve hand-
wheel counterclockwise.
WARNING: Do not ignite burners when leak checking.
Check for leaks by wetting the connections with the soap and water solution and
watching for bubbles. If bubbles form or if a bubble grows, there is a leak.
11