UPPER ZONE:
The default temperature setting is 18°C. However, the temperature can be set from 15°C - 20°C.
Set the desired temperature using the
Confirm your setting by pressing the SET buttons. If you do not confirm by pressing this key, the
change in temperature setting will not take effect.
N.B.: to function correctly, your cabinet must be placed in a room with a temperature of 12 - 30 °C.
Alarms
If the temperature inside the cabinet is 6°C above or below the temperature setting, for over 3 hrs, the
control activates the alarm and the warning light
NB: If you have loaded your cabinet with a large number of bottles, it can take several hours
for your wine cabinet's temperature to stabilise. The warning light
a while then check again. If the alarm warning light does not disappear, contact your retailer.
When commissioning your cabinet, or after significant changes to the temperature setting, it can take
several hours for your wine cabinet to stabilize and display the new desired temperature.
Wait a few days. If the temperature does not stabilise, contact your retailer.

Everyday maintenance of your wine cabinet

Your ARTEVINO cabinet is a tried and tested appliance. The following few operations will allow your
cabinet to perform at its best for many years to come.
1) Clean the water drain at the bottom of the wine cabinet. Pay attention that nothing is blocking this drain.
2) Regularly vacuum (twice a year) the condenser (black metal grill attached to the back of your wine
cabinet).
3) Once a year, thoroughly clean the inside of your wine cabinet, remembering to unplug it after removing
your bottles (use a gentle cleaning product and water, remember to rinse well and then dry it with a soft
rag).
4) It is often necessary to clean the door seal. Using unsuitable cleaning products can cause premature
ageing of the seals. Certain rules must therefore be followed: whenever you clean the seal, always rinse
off any cleaning product with clear water. All traces of cleaning product must be removed from the seal.
ARTEVINO only recommends using a mild soapy solution. If this proves insufficient, it is possible to
occasionally use an ethanol-based solution, provided that the concentration used is less than 10% and that
the seal is then rinsed thoroughly with clear water.
14
and
buttons.
appears.
may then appear. Wait

Operating faults

When starting up
• The compressor does not work >
check that the wall socket is supplied with power by plugging in
another electrical appliance.
• The compressor never stops >
put your hand on the condenser (grill located on the back of the
appliance). If the condenser is cold, contact your retailer.
If the condenser is hot, set your cabinet (ST1) to the maximum temperature setting value. If the compressor
still does not stop, contact your retailer.
• The wine cabinet does not switch on >
contact your dealer
ANY WORK CARRIED OUT BY TECHNICAL SERVICES NOT APPROVED BY ARTEVINO
SHALL RENDER THE WARRANTY NULL AND VOID.
THE USE OF A GLASS DOOR CAN AFFECT THE PERFORMANCE OF YOUR WINE CABINET
IN SOME EXTREME TEMPERATURE CONDITIONS.

Standards

Your product meets the following standards:
1- Safety
Directive
2006/95/CE
Standard
EN60335-1: 2012+A11: 2014
EN60335-2-24/ 2010
2- EMC
Directive
2004/108/CE
Standard
62233:2008
3- Environment
Directive 2010/30/UE
Regulation 1060/2010
R600a
Depending on the country, ArteVino
wine cabinets may contain flammable
refrigerant gas (R600a: ISO BUTANE).