PerfectCharge MCP1204/1207
The battery charger can be operated in three operating modes:
Mode 1: Charge mode with 14.4 V
This mode is used for lead, gel and maintenance-free batteries.
Mode 2: Charge mode with 14.7 V
This mode is used for AGM batteries.
Mode 3: Voltage supply with 13.7 V (battery is not connected)
This mode is used as a power supply function, e.g. for supplying voltage
to the vehicle in the event of replacing a battery, or during maintenance
work using service devices.
The device can be installed on a wall using the wall bracket for stationary
storage (accessory).
Furthermore, an external battery indicator (accessory) can be used. This
shows the battery capacity and can be connected to the battery permanently
using a connection cable with cable lugs. When it indicates the battery is
empty, the battery charger can be connected to the battery indicator and the
battery can be charged directly.
The battery indicator can be attached to a wall or to a wall bracket for the
battery charger using a wall bracket.