19
PATIENT Port
Antibacterial Filter
Autoclavable
Silicone Tube
NEVER USE THE DEVICE WITHOUT JAR AND / OR PROTECTION FILTER
MAKE SURE THAT CHILDREN AND/OR MENTALLY ILL PEOPLE DO NOT USE THE DEVICE WITHOUT
ADULT SURVEILLANCE
RISK OF ELECTROMAGNETIC INTERFERENCE AND POSSIBLE REMEDIES
This section contains information regarding the conformity of the compliance with the EN 60601-1-2 Standard
(2015).
The SUPER TOBI surgical aspirator is an electro-medical device that requires particular precautions regard-
ing electro-magnetic compatibility and which must be installed and commissioned according to the elec-
tro-magnetic compatibility information supplied. Portable and mobile radio communication devices (mobile
phones, transceivers, etc.) may interfere with the medical device and should not be used in close proximity
with, adjacent to or on top of the medical device. If such use is necessary and unavoidable, special precau-
tions should be taken so that the electro-medical device functions properly in its intended operating configu-
ration (for example, constantly and visually checking for the absence of anomalies or malfunctions). The use
of accessories, transducers and cables differing from those specified, with the exception of transducers and
cables sold by the appliance and system manufacturer as spare parts, can lead to an increase in emissions
or in a decrease of the immunity of the device or system. The following tables supply information regarding
the EMC (Electromagnetic Compatibility) characteristics of the electro-medical device.
Guidance and manufacturer's declaration – electromagnetic Emissions
The SUPER TOBI SUCTION UNIT is intended for use in the electromagnetic environment specified below. The customers
or the user of the SUPER TOBI SUCTION UNIT should make sure that it's used in such an environment.
Emissions test
Irradiated / Conducted
emissions CISPR11
Irradiated / Conducted
emissions CISPR11
Harmonic emissions
EN 61000-3-2
Voltage fluctuations / flicker
emissions EN 61000-3-3
Compliance
Electromagnetic environment - guidance
Group 1
The SUPER TOBI SUCTION UNIT only used RF energy only for its
internal functioning. Therefore, its RF emissions are very low and
are not cause interference in proximity of any Electronic appliances.
Class [B]
The SUPER TOBI SUCTION UNIT can be used in all environments,
including domestic and those connected directly to the public mains
distribution that supplies power to environments used for domestic
Class [A]
scopes.
Complies
ENGLISH
VACUUM Port
Regulator Knob
Vacuum Indicator
(kPa /Bar)
ON/OFF Switch
Conical Fittings
Vacuum