BTL7-A/C/E/G504-M_ _ _ _ -TT2/3-S32/KA_ _/FA_ _
Micropulse Transducer - Rod Style
Electrical connection
S32
Cable
Pin
color
-A504
1
YE yellow
2
GY gray
3
PK pink
4
RD red
5
GN green
0...10 V 2)
6
BU blue
7
BN brown
8
WH white
Shielding and cable routing
Defined ground!
The transducer and the control cabinet must be
at the same ground potential.
Shielding
To ensure electromagnetic compatibility (EMC), observe
the following:
Connect the transducer and controller using a shielded
cable. Shielding: Copper filament braided, at least 85%
coverage.
Connector version: Shield is internally connected to
connector housing.
Cable version: On the transducer side, the cable
shielding is connected to the housing. Ground the
cable shielding on the controller side (connect with the
protective earth conductor).
Magnetic fields
The position measuring system is a magnetostrictive system.
It is important to maintain adequate distance between the
transducer cylinder and strong, external magnetic fields.
Cable routing
Do not route the cable between the transducer, controller,
and power supply near high voltage cables (inductive stray
noise is possible). The cable must be routed tension­free.
Bending radius for fixed cable
The bending radius for a fixed cable must be at least five
times the cable diameter.
Cable length
Max. 20 m 1)
BTL7­A/G
Max. 50 m 1)
BTL7­C/E
1) Prerequisite: Construction, shielding and routing preclude the effect of
any external noise fields.
Installation
NOTICE!
Interference in function
Improper installation can compromise the function of the
transducer and result in increased wear.
► The mounting surface of the transducer must make
full contact with the supporting surface.
► The bore must be perfectly sealed (O­ring/flat seal).
www.balluff.com
Interface BTL7-...
-G504
-C504
Not used 1)
0...20 mA 2) 4...20 mA 2)
0 V
Not used 1)
La (programming input)
10...10 V 2)
Not used 1)
GND 3)
10...30 V
Lb (programming input)
-E504
Pin assignment of S32 (view of connector pins of
transducer), 8­pin M16 circular plug
1) Unassigned leads can be connected to GND on
the controller side but not to the shield.
2) Factory settings, freely configurable using PC
software.
Reference potential for supply voltage and
3)
EMC­GND
.
Screw the transducer thread into the mounting hole
(max. torque 150 Nm).
From 500 mm nominal length: support the rod and tighten
it at the end if necessary.
If installed in a hydraulic cylinder, the magnet should not
make contact with the outer rod. Minimum bore diameter
in the support piston:
Rod diameter
21 mm
Startup
DANGER
Uncontrolled system movement
When starting up, if the position measuring system is
part of a closed loop system whose parameters have not
yet been set, the system may perform uncontrolled
movements. This could result in personal injury and
equipment damage.
► Persons must keep away from the system's
hazardous zones.
► Startup must be performed only by trained technical
personnel.
► Observe the safety instructions of the equipment or
system manufacturer.
1. Check connections for tightness and correct polarity.
Replace damaged connections.
2. Turn on the system.
3. Check measured values and adjustable parameters
regularly (especially after replacing the transducer or
after repair by the manufacturer). Recalibrate the
transducer, if necessary.
Bore diameter
At least 27 mm