The Hozelock Cyprio Cascade 1500 low
voltage pump is designed for submersible use
only. The pump does not use oil or grease
for lubrication and can be used safely in
ponds containing fish or plants. The motor
consists of a sealed stator and water-cooled
permanent magnet rotor. All electrical
components are isolated from the water.
WARNING: SAFETY AND
ELECTRICAL CONNECTIONS.
1. WARNING - Always unplug or disconnect
all appliances in the pond from the
electricity supply before putting your
hands in the water whilst equipment is
being installed, repaired, maintained or
handled.
2. Position the transformer in a garage or
shed close to the mains voltage supply.
The transformer is not waterproof and
must be kept dry and under cover –
allowing for sufficient air circulation.
Do not position the transformer in direct
sunlight, eg.. greenhouse, window sills,
etc.. as high temperatures may cause
overheating.
3. Do not use the supply cable to lift the
pump, as this may cause damage. We
recommend fitting a lifting cord to the
handle eye on the top of the strainer cage
when the pump is installed in deep water.
4. Do not operate or leave the pump in
freezing conditions.
5. Do not allow the pump to run dry.
6. Check that the voltage marked on the
pump corresponds to the low voltage
supply.
7. Do not operate this pump without the
strainer cage attached. Using the pump
without a strainer may invalidate your
warranty.
8. The pump must only be connected to a
safety isolating transformer with a 24V
output, such as the one supplied with this
product.
9. Consult a qualified electrician or local
authority if in any doubt about wiring to
the mains supply.
ACCESSORY ASSEMBLY
Tee Piece.
1. Locate the fountain flow adjuster (Fig1- A)
to the tee piece body with the peg
positioned downwards to engage in the
tee. Push in fully and snap them together.
2. Locate the valve stem (B) to the waterfall
flow adjuster (C) and snap them together.
Screw the valve assembly into the longer
boss (D) on the tee piece. See Fig 1.
Telescopic Stem
1. Slide the Inner Tube (E) through the
Telescopic Stem Nut (F) and "O" ring (G).
Push the Inner Tube into the Outer Tube
(H) and gently screw down the nut. The
finishing position of the tee piece is not
important. The maximum to minimum
range of the Telescopic stem is 150mm
(6") (See Fig 2).
Bell Fountain.
1. Locate the Bell Support (J) to the Bell
Main Body (I) and push fully home.
2. Position the Bell (K) to the Body Assembly
and press into the central location.
See Fig 3.
2
TRANSFORMER INSTALLATION
Connect the pump to the transformer as
follows; (see Fig 10).
1. Plug the pump lead into the socket
provided on the flying lead for the
transformer. If an extension lead is
required, Hozelock Cyprio can provide
extension leads.
2. The cable supplied with this pump cannot
be replaced if the pump is damaged.
3. Plug the transformer into the socket. Take
care to position the cable so that it will
not place un-necessary pulling load on
transformer by leaving the flying lead
with slack cable.
4. The pump can now be switched on. Refer
to the "Pump Installation" section for
details on fountain height adjustment.
NOTE: This transformer is protected by a
single-shot thermal fuse. If this device
operates, the pump will stop working and
the transformer will have to be replaced.
This will only occur if the transformer
overheats. This can be caused by exposure
to direct sunlight. Ensure that the
transformer operates in a shaded area.

PUMP INSTALLATION

Position
Construct a solid and level platform on which
to place the pump. For installations using the
fountain tops directly on the Tee Piece, the
top level of the platform should be 300 mm
(12") below the water level. For installations
using the fountain tops directly on the Tee
Piece and Telescopic Stem , the top level of
the platform should be 450 mm (18") below
the water level.
Fountain Only.
(See Fig 7 for general installation guide)
1. Place the pump next to the pond and
route the cable back to the mains supply.
2. Position the pump with the Tee Piece
Assembly and if required the Telescopic
Stem with the fountain fitted in the
desired position in the pond. The 2 and 3
tier fountain heads simply snap onto the
fountain stem (See Fig 4).
3. The fountain height can be regulated to
suit your needs by rotating the Fountain
Flow Adjuster. See Fig 5 (L).
4. If required, the 2-Tier Fountain head, Fig 5
(M), can be used to achieve an alternative
and higher display pattern than the 3-Tier,
Fig 5 (N)
5. The Bell Fountain creates a decorative
waterbell. The size of the bell can be
regulated by adjusting the flow through
the Tee Piece by rotating the fountain
flow adjuster and or by raising or
lowering the top of the Bell in main Bell
Body.
6. The ball joint on the bottom of the tee
Piece (See Fig 5, O) can be used to adjust
the fountain angle so that it is vertical.
Fountain and Waterfall.
(See Fig 8 for general installation guide)
1. Position the pump as previously described.
2. Attach a suitable length of 25 mm (1")
hose to the Threaded Hose tail, Fig 5 (P),
and secure with a suitable hose clip and
position the outlet end of the hose in the
desired position.
3. Screw the Threaded Hose tail onto the
waterfall outlet side of the Tee Piece.
4. The combination of waterfall and
fountain will reduce the fountain height
that can be achieved.
5. Once the pump is operating the flow of
the waterfall and the height of the
fountain can be independently adjusted.
Waterfall Only.
(See Fig 9 for general installation guide)
1. Position the pump as previously described.
2. Attach a suitable length of 25 mm (1")
hose to the Threaded Hose tail and secure
with a suitable hose clip and position the
outlet end of the hose in the desired
position.
3. For maximum waterfall flow, screw the
Threaded Hose tail directly onto the
outlet of the pump. Some installations
require the flow of the water to be
adjusted. In these cases, screw the Tee
Piece to the outlet of the pump, screw the
Threaded Hose tail to the water fall
outlet boss and adjust the flow using the
waterfall flow adjuster, Fig 5 (Q), to suit
your needs.
MAINTENANCE
The Hozelock Cyprio range of Cascade pumps
have been designed to allow fast and easy
maintenance. As with all pumps of its kind,
occasionally it will become necessary to clean
the Strainer Cage and Fountain Spray head
ring.
ALWAYS UNPLUG OR DISCONNECT ALL
APPLIANCES IN THE POND FROM THE
ELECTRICITY SUPPLY BEFORE PUTTING YOUR
HANDS IN THE WATER OR STARTING
MAINTENANCE.
Fountain Head
1. Place a coin or similar in the slot and
gently lever off the fountain head.
2. Rinse in clean water and reassemble.
Strainer.
1. Remove the accessories from the pump
outlet.
2. Holding the pump in one hand, press the
release button (R) on the top of the pump
and open Strainer Cage. See Fig 5.
3. Slide the pump out of its location and
wash/rinse the Strainer Cage with clean
water. The hinges on the Strainer Cage
should also be washed clean at this time.
4. Reassemble the pump.
Rotor Assembly.
1. Remove the Strainer Cage as described
above.
2. Release the Pump Chamber, Fig 6 (S), by
rotating it until the two retaining tongues
are clear of the lugs on the Motor Body.
3. Gently pull the Pump Chamber squarely
away from the Motor Body.
4. Pull the Rotor Assembly out of the Motor
Body. See Fig 6 (T).
5. Wash out all of the components in clean
water. Do not use detergents or other
chemical cleaners.
6. Replace the Rotor Assembly into the
Motor Body and refit the Pump Chamber
and Strainer Cage.
ALL YEAR PUMP CARE
A quick daily check should be carried out to
ensure that the pump is performing
satisfactorily.
Once a week- Remove and clean the Strainer
Cage and Fountain Head in accordance with
the general maintenance notes. Depending
on pond water conditions, cleaning may be
required more frequently.
Once a year- Completely disassemble the
pump including the Rotor Assembly as
described in the general maintenance notes
and wash all components in clean, fresh
water. Replace worn or broken parts.
HOZELOCK CYPRIO 3 YEAR
GUARANTEE
If this pump, excluding the Rotor Assembly,
becomes unserviceable within 3 years of the
date of purchase it will be repaired or
replaced at our option free of charge, unless
in our opinion it has been damaged or
misused.
Liability is not accepted for damage due to
accident, improper installation or use.
Liability is limited to replacement of a faulty
pump. This guarantee is not transferable. It
does not affect your statutory rights.
To obtain the benefits of the guarantee,

Publicidad

Tabla de contenido
loading

Tabla de contenido