SERVICING
Regular maintenance is essential for good stove operation.
FAILURE TO CARRY OUT MAINTENANCE LEADS TO FORFEITURE OF THE GUARANTEE
Before carrying out any maintenance, disconnect the device from the mains power supply.
DAILY CLEANING
Clean with a vacuum cleaner. The whole process takes a few minutes a day.
USING A VACUUM CLEANER when the stove is cold:
- Vacuum-clean the door, vacuum-clean the hearth and vacuum-clean the space around the combustion chamber where
the ash falls (there is no extractable ash pan).
- Remove the combustion chamber or clean it with a scraper, and unblock any blocked holes on all sides.
- Vacuum-clean the combustion chamber compartment, clean touching edges and replace the combustion chamber.
- If necessary clean the glass (when cold).
NEVER loosen the Allen screws inside the firebox: the loader will fall.
NEVER VACUUM-CLEAN HOT ASH, since it may damage the vacuum cleaner.
After a few months use dry air (PC keyboard type) to clean, with the stove switched off, the flow sensor in the combu-
stion air intake pipe.
EMPTY THE HOPPER AND VACUUM-CLEAN THE BOTTOM IF THE STOVE IS NOT IN USE, and in any case
every 15 days.
EVERY SEASON
(by the Dealer)
- General internal and external cleaning.
- Carefully clean the heat exchange pipes.
- Clean/check the exhaust pipes.
NEVER loosen the Allen screws inside the firebox: the loader will fall.
- Carefully clean and descale combustion chamber and corresponding compartment.
- Clean fan and mechanically inspect play and fastenings.
- Clean smoke duct (replace gasket on smoke outlet pipe).
- Clean smoke extractor fan compartment, clean flow sensor and check thermocouple.
- Clean, inspect and descale ignition heating element compartment and change the heating element itself if necessary.
- Clean/check display-control panel.
- Visually inspect electric cables, connections and power cord.
- Clean pellet hopper and check screw feeder-gearmotor assembly play.
- Change door seal.
- Test screw feeder loading, ignition, operation for ten minutes and shutdown.
If the stove is used frequently, it is advisable to clean the smoke duct every 3 months.
OPTIONAL EXTRAS
REMOTE CONTROL (code n. 633280)
It is possible to buy a remote control to turn the stove on and off and adjust it remotely.
Refer to instructions on page 22.
REMOTE IGNITION BY TELEPHONE (code n. 281900)
The stove may be turned on remotely by phone (code 620550) by having a Dealer connect a dialler to the electronic
circuit board (AUX port).
TRESTLE Aux port connection (code 620550).
REMEMBER TO VACUUM THE COMBUSTION CHAMBER BEFORE EACH IGNITION
Should ignition fail, DO NOT re-ignite until you have emptied the combustion chamber.
25