Problem
Indicator lamps and alarm function
The "Status
LED"
on the
B
unit flashes red
once each 3
seconds.
EN
The "status
LED"
on the
B
unit flashes red
at intervals of 3
seconds.
The "Status
LED"
on the
B
unit flashes red
four times each
3 seconds.
A continuous
confirmation
tone is audible.
48
Potential cause
Malfunction.
Air in pipe.
Filter seal on the
water connection
hose dirty.
Water connection
hose kinked.
Shut-off valve on
the water connec-
tion hose closed (-).
Malfunction.
Malfunction.
Solution
> Switch off
SensoWash
.
®
> Switch on
SensoWash
again.
®
If flashing does
not stop:
> Cut off power
supply.
> After 30 sec.
connect it again.
> Activate the self-
cleaning.
> Clean the filter seal.
> Check the hose rou-
ting.
> Open the shut-off
valve (|).
> Turn off "Water
temperature"
> Activate any shower
function.
> Cut off the power
supply.
> After 30 sec.
connect it again.
Ch.