Kohler K-13462 Manual Del Usuario página 9

Ocultar thumbs Ver también para K-13462:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting (cont.)
Symptoms
Probable
Causes
K. Solenoid is
broken.
2.
Low flow.
A. Filter is
plugged.
B. Supply
pressure is
low.
C. Aerator is
plugged.
Constant
A. Filter is
3.
water flow.
plugged.
B. Diaphragm
seal is
damaged or
dirty.
C. Solenoid is
not working.
4.
Sporadic
A. The faucet
water flow.
is angled
incorrectly to
deck or
misaligned
with user area.
B. The wires
are pinched or
damaged.
5.
Sensor
A. Low
flashes once
voltage.
approximately
every 2
seconds. The
product
continues to
operate.
Kohler Co.
Recommended Action
K. Order a new solenoid service
kit.
A. Clean or replace the filter.
B. Check incoming water pressure.
Pressure should be at least 20 psi
(137 kPa).
C. Remove the aerator and clean it.
For calcium/mineral deposits, soak
the aerator plastic insert in a 50:50
mixture of vinegar and water. Soak
only the insert and no other
components.
A. Clean or replace the filter.
B. If the diaphragm is cut or torn,
order a new diaphragm assembly.
Clean or replace the diaphragm.
C. Order and install a new solenoid
assembly.
A. Verify that the faucet is mounted
according to the installation
directions. Ensure that the faucet is
installed in a position that is above
the rim of the lavatory.
B. Remove the spout and verify
that the wires are tucked inside the
spout before reassembling.
A. Replace the power supply.
9
1124215-5-B

Publicidad

Tabla de contenido
loading

Tabla de contenido