Connection of the protective conductor (PE):
Sensitivity when switching (with regard to the ambient brightness):
Time setting (switching off delay):
Reach Setting:
Function test:
Ensure that the motion detector is not obscured. Ensure that the coverage area is not restricted by items such as
through large furniture. To set the detection range and the daylight test, turn the knobs to the positions shown. The
If a lamp with protective earth contact is connected and a junction box is
not installed, the protective earth must be bridged from the supply line to
the lamp by means of an additional terminal in the housing of the motion
detector.
With this switch the switch-on sensitivity can be set to 10 (slide up) or 2.000 LUX
(slide down) depending on the ambient brightness. Note: When testing the device
in daylight, set the switch to the position shown.
The following times can be set:
5s, 30s, 1min, 3min, 5min, 8min
Note: The time is restarted if a movement is detected by the sensor before the end
of the set period.
With this switch, the detection range can be set to 3m (slide up) or 6m (slide down).
10