Before installation .............................................................................. 1
Selecting installation site ................................................................... 2
Preparations before installation ......................................................... 2
Installation procedures for fresh air intake duct connection............... 3
Indoor unit installation........................................................................ 3
Refrigerant piping work...................................................................... 3
Drain piping work............................................................................... 4
Electric wiring work............................................................................ 5
Wiring example and how to set the remote controller ....................... 5
Wiring example.................................................................................. 6
Field setting ....................................................................................... 6
Installation of the decoration panel.................................................... 7
Test operation .................................................................................... 7
Maintenance ...................................................................................... 7
Wiring diagram .................................................................................. 9
READ THESE INSTRUCTIONS CAREFULLY BEFORE
INSTALLATION. KEEP THIS MANUAL IN A HANDY
PLACE FOR FUTURE REFERENCE.
IMPROPER
INSTALLATION
EQUIPMENT OR ACCESSORIES COULD RESULT IN
ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR
OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY
TO USE ACCESSORIES MADE BY PANASONIC WHICH
ARE SPECIFICALLY DESIGNED FOR USE WITH THE
EQUIPMENT AND HAVE THEM INSTALLED BY A
PROFESSIONAL.
IF UNSURE OF INSTALLATION PROCEDURES OR USE,
ALWAYS CONTACT YOUR PANASONIC DEALER FOR
ADVICE AND INFORMATION.
B
EFORE INSTALLATION
I
Leave the unit inside its packaging until you reach the
installation site. Where unpacking is unavoidable, use a sling of
soft material or protective plates together with a rope when
lifting, this to avoid damage or scratches to the unit.
Refer to the installation manual of the outdoor unit for items not
I
described in this manual.
Precautions
I
Do not install or operate the unit in rooms mentioned below.
Places with mineral oil, or filled with oil vapour or spray like in
kitchens. (Plastic parts may deteriorate.)
Where corrosive gas like sulphurous gas exists. (Copper tubing
and brazed spots may corrode.)
Where volatile flammable gas like thinner or gasoline is used.
Where machines generating electromagnetic waves exist.
(Control system may malfunction.)
Where the air contains high levels of salt such as air near the
ocean and where voltage fluctuates a lot (e.g. in factories). Also
in vehicles or vessels.
CS-20~125UMHPP
Urban Multi air conditioner
4PW12338-1A
CS-80UMHPP
Urban Multi air conditioner
CS-100UMHPP
CS-125UMHPP
Page
OR
ATTACHMENT
OF
When selecting the installation site, use the supplied paper
I
pattern for installation.
I
Do not install accessories on the casing directly. Drilling holes in the
casing may damage electrical wires and consequently cause fire.
Accessories
Check if the following accessories are included with your unit.
Also used as packing
material
Clamp
Paper pattern for
1 pc.
installation 1 pc.
Screws M5
Washer for hanging
For paper pattern
bracket 8 pcs.
for installation 4 pcs.
Insulation for fitting1 each
for liquid pipe
for gas pipe
Optional accessories
I
There are two types of remote controllers: wired and wireless.
Select a remote controller according to customers request and
install in an appropriate place.
Refer to catalogues and technical literature for selecting a
suitable remote controller.
A decoration panel is also required for this indoor unit.
I
For the following items, take special care during
construction and check after installation is finished
Tick 
when
checked
Is the indoor unit fixed firmly?
I
The unit may drop, vibrate or make noise.
Is the gas leak test finished?
I
It may result in insufficient cooling.
I
Is the unit fully insulated?
Condensate water may drip.
I
Does drainage flow smoothly?
Condensate water may drip.
Does the power supply voltage correspond to that shown on the
I
name plate?
The unit may malfunction or components may burn out.
I
Are wiring and piping correct?
The unit may malfunction or components may burn out.
I
Is the unit safely grounded?
Dangerous at electric leakage.
Is the wiring size according to specifications?
I
The unit may malfunction or components may burn out.
I
Is nothing blocking the air outlet or inlet of either the indoor or
outdoor units?
It may result in insufficient cooling.
Are refrigerant piping length and additional refrigerant charge
I
noted down?
The refrigerant charge in the system might not be clear.
Installation
and operation manual
Drain hose 1 pc.
Sealing 2 pcs.
Other: installation and
operation manual