5.2 Technical data
Hydraulic data
Maximum delivery head
Maximum Horizontal
Delivery
Maximum altitude
DN of suction connection
DN of pressure connection
Temperature range
Fluid temperature range
Ambient temperature
Electrical data
Motor protection rating
Insulation class
Frequency
Voltage
Rated current
5.3 Scope of delivery
• Lifting system
• Operating manual
For HiDrainlift 3-24:
clamp 20x32 (x2), clamp 25x40 (x1), inlet lateral plug (x2), plug (x1),
outlet elbow (x1).
For HiDrainlift 3-35 and HiDrainlift 3-37:
outlet elbow (x1), 2-outlet bushing (x1), clamp 32x55 (x8), clamp 25x40 (x1),
inlet bush (x3), inlet lateral plug (x2), screw (x2), fixation strip (x2).
5.4 Description
HiDrainlift 3-24 (Fig. 1)
1 - Elbow
2 - inlet lateral plug (x2)
3 - Plugs
4 - Clamps (2 x 20x32; 1 x 20x40)
HiDrainlift 3-35 and HiDrainlift 3-37 (Fig. 2)
1 - inlet bush (x3)
2 - Elbow
3 - 2-outlet bushing
4 - inlet lateral plug (x2)
5 - Fixation strip (x2)
6 - Screw (x2)
7 - Screw clamp (x2 for each part number)
24
HiDrainlift 3-24
HiDrainlift 3-35
4 m
5 m
40 m
50 m
1000 m
1000 m
DN40
DN40
DN32
DN32
+5°C à +60°C
+5°C à +35°C
(5 min. max.)
Max. +40°C
Max. +40°C
IP 44
IP 44
Class I
Class I
50 Hz
50 Hz
220/240 V
220/240 V
1.22 A
1.7 A
HiDrainlift 3-37
7 m
70 m
1000 m
DN40
DN32
+5°C à +75°C
(5 min. max.)
Max. +40°C
IP 44
Class I
50 Hz
220/240 V
2 A
09/2014