laser remote controls. This is the normal, default operating
mode for the DW079 laser unit.
To activate Public Mode:
• After being fully powered off, the laser unit will power up
in Public Mode.
OR
• Press and hold the speed/rotation button (E) (open
padlock symbol beside the button).
Private Mode
The laser unit will only accept commands from the
DW0794 remote control designated by the user.
To activate Private Mode:
• Press and hold the scan mode button (F) on the laser
unit control panel (closed padlock symbol) and at the
same time press and hold the remote control scan
mode button (R) (closed padlock symbol).
After 4 seconds, both the laser unit and the remote
control will enter Private Mode. As confirmation,
the laser unit will beep and the laser control panel
LED (L) (next to the closed padlock symbol) and the
remote control LED (T) (next to the closed padlock
symbol) will flash.
No Remote Mode
This mode causes the laser unit to ignore all remote
control commands.
To activate No Remote Mode:
• Press and hold the scan mode button (F) on the laser
unit control panel (closed padlock symbol), but do
not press any button on the remote control.
After 4 seconds, the laser unit will beep and the LED
(L) next to the padlock symbol will flash.
Using the Wireless
Remote Control (Fig. 4)
The remote control allows one person
to operate and setup the laser from a
distance. The remote control features a
power button (M), manual mode button
(N), four arrows (O, PP), speed/rotation
button (Q) and scan mode button (R).
Two LED indicator lights are on the
remote control: transmit (S) and private
mode (T).
REMOTE CONTROL: POWER
BUTTON
Press the remote control power button
(M) to put the laser unit into Sleep
Mode. In Sleep Mode all laser unit
functions shut off except for a periodic blink from the power LED
(L) on the control panel of the laser unit. Press the remote control
power button again to "wake up" the laser unit.
NOTE: To completely power the laser unit off, the power button on
the control panel of the laser unit must be pressed. The laser unit will
also automatically power off if it is left in Sleep Mode for 8 hours.
REMOTE CONTROL: MANUAL MODE BUTTON
To activate Manual Mode, press and hold the remote control manual
mode button (N) for 3 seconds. Manual Mode must be activated to
use manual sloping. (Refer to Using Manual Slope Mode for a
complete description of this function.)
To re-engage full self-leveling, press and hold the manual mode
button again for 3 seconds.
11
FIG. 4
S
N
M
O
P
R
Q
T