Interface description
Audio module on the video aluminum outdoor station
1
2
16
15
14
13
12
11
10
9
8
7
6
5
2
1
1- 9
024
3
X100
X1 0
4
No.
Description
1
Connector for camera module
2
Connector for device software update
3
Plug-in clamps (COM-NC-NO) for floating output, door opener (30
V AC/DC 1 A)
4
Plug-in clamps(Lock-GND) for door opener (18 V 4 A impulsive, 250
mA holding)
5
Plug-in clamps(DC-GND) for additional power supply
6
Plug-in clamps(a-b) for Bus connection
7
Connector for induction loop module
8
Connector for next module
9
Connector for exit pushbutton
4
3
10
Connector for sensor to check the door status
11
Rotary switch to set the address of OS (1-9)
12
Set feedback tone of push button: ON/OFF
13
Configure push button as single column or double columns (ON=
double columns; OFF= single column)
14
Configure function of 1st / 2nd push button
3->OFF, 4->OFF=call indoor station/call indoor station;
3->ON, 4->OFF=switch on lightings/call indoor station;
3->OFF, 4->ON=call guard unit / call indoor station;
3->ON, 4->ON=switch on lightings / call guard unit.
15
Adjust loudspeaker volume
16
Adjust door lock release time, 1-10 seconds
No.
Description
1
Station
Jumper to set the address of default outdoor station.
2
X100 X10 X1
Jumper to set the address of the indoor station.
Master /Slave function
3
5
6
Only one indoor station in each apartment must be set as "Master"
7
(Jumper should be set as 'M/S on'). All additional indoor stations in
the same apartment must be set as "Slave" (Jumper should be set
as 'M/S off').
Terminal resistor
4
In video installations or mixed audio and video installations, the
Jumper must be set as 'RC on' on the last device of the line.
5
a b = Bus connection
6
a potential free contact, such as a doorbell pushbutton
7
DC GND = Additional power supply