14 /40 Bosch Rexroth AG | Electric Drives and Controls

6 SE311 Control Signals

5.3
Interface X 7: 24 V I/O
Two inputs and outputs, which can be
processed in the tightening program, are
integrated in the SE311.
To use the inputs via external limit switches,
the 24 V potential can be used by the internal
power supply (pins 5 and 6).
1
2
3
4
5
6
Figure 5: Strip terminal, 6-pin
Type of plug: e. g. Phönix Contact, MC 1.5/6-
ST-3.5
Pin
Signal Description/
Function
1
IN1
Input 1
2
IN2
Input 2
3
OUT1
Output 1
4
OUT2
Output 2
5
24 V
24 V for inputs
6
0 V
Reference
potential for
outputs
Table 4:
6
6.1
A tightening cell is defined as the installed
hardware for at least one tightening channel
and at least one data interface for
communication with the operating or
evaluation program or the superior controller.
This includes the corresponding tightening
programs and tightening applications.
A tightening channel is controlled by an
SE311 tightening controller. The KE310 or
KE312 and SE311 communicate with each
other via an internal bus system.
Up to 48 tightening programs can be stored
in a tightening controller. Only 1 tightening
program can be started at a time.
6.2
The tightening cell communicates with the
superior controller via control signals. A PLC
assignment table determines which control
signals are assigned to the inputs/outputs.
The inputs/outputs are assigned in the
Voltage/
BS300 operating program.
Current/
For more information, refer to:
Standard
– the online guide in the operating program
24 V DC/
(programming the assignment table),
DIN 19 240
– the system documentation, chapter 5
24 V DC/
"Control signals" (3 609 929 918) (signal
DIN 19 240
description, sequence examples, and
24 V DC/
100 mA/
chronological sequences).
DIN 19 240
24 V DC/
100 mA/
DIN 19 240
24 V DC/
300 mA/
DIN 19 240
24 V DC /
DIN 19 240
SE311 | 3 609 929 983/1.0
SE311 Control Signals
Tightening cell
Control signals

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Se311 3 609 929 983

Tabla de contenido