Descargar Imprimir esta página

English - jbc Advanced Serie Manual Del Usuario

Ocultar thumbs Ver también para Advanced Serie:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

We appreciate the trust you have placed in JBC by purchasing this equipment. It
has been manufactured with the strictest quality standards in order to give you the
best possible service.
Before using this equipment, we recommend you read these instructions carefully.
Air pressure desoldering system
MS 9015 Ref.9015000
Desoldering air filter
The MS 9015 is a suction pump that needs an
external compressed air circuit. It has a Venturi
vacuum generator that provides exceptional
suction capacity.
You can connect the following stations from the
Advanced range: DI 2860, DD 5700, DM 6700
and the MS 9000.
Compressed air input.
Maximum pressure: 6 bars.
Aspiration inlet
Connection
Spare filters
Ref.0005966
Ref.0780637
Technical specifications
- Maximum compressed air pressure: 6 bars.
- Recommended air pressure: 5 bars.
- Supply: 24V.
- Power: 5W.
- Weight of complete unit: 1,6 Kgs.
- ESD protected housing.
Typical surface resistance: 10
square.
- Complies with CE standards on electrical
safety, electromagnetic compatibility and
antistatic protection.
- RoHS compliant.
This product should not be thrown in the
garbadge.
Changing the pump inlet filter
-
Disconnect the desoldering iron tube and
unscrew the stopper.
-
Take out the 2 paper filters, throw away
those which are soiled and replace them
with new ones. Always use 2 filters.
-
Screw on the stopper and connect up the
tube.
-
Check the airtightness.
JBC reserves the right to make technical changes without prior
notification.
1

ENGLISH

5
11
-10
Ohms/

Publicidad

loading

Este manual también es adecuado para:

Ms 9015