Mounting
Mounting (4-Post Rackmount)
The UPS includes rackmount rails for 4-post rackmounting. The user must determine the fitness of hardware and procedures before mounting.
If hardware and procedures are not suitable for your application, contact the manufacturer of your rack or rack enclosure. The procedures
described in this manual are for common rack and rack enclosure types and may not be appropriate for all applications.
WARNING! The UPS system is extremely heavy. Use caution when lifting and mounting. User must properly stabilize the UPS when
lifting and mounting.
Connect the two segments of each shelf
1
using the included attached screws and
wing nuts. Leave the screws slightly
loose so that the shelves can be adjusted
in the next step.
2
Adjust each shelf to fit your rack, then
mount them in the lowest available
space of your rack with the screws, nuts
and washers provided. Note that the
support ledges should face inward.
Tighten the wingnuts that connect the
shelf segments.
Attach mounting ears to the front
3
mounting holes of your UPS using the
screws provided. The ears should face
forward.
4
Using one or more assistants, lift your
UPS and slide it onto the mounting
shelves. Attach your UPS to the rack by
passing screws, nuts and washers (user-
provided) through its mounting ears and
into the rack rails.
Mounting (2-Post Rackmount)
If you mount this UPS model in 2-post racks, it requires the addition of a Tripp Lite 2-Post Rackmount Installation Kit (model:
2POSTRMKITWM, sold separately). See Installation Kit owner's manual for installation procedure.
Mounting (Tower)
Mount the UPS system in an upright, tower position using 2-9USTAND base stands (optional). The user must determine the fitness of hardware
and procedures before mounting.
WARNING! The UPS system is extremely heavy. Use caution when lifting and mounting. User must properly stabilize the UPS when
lifting and mounting.
Adjust the stands to a width of 6.93
1
inches (176 mm) for a UPS. Adjust the
stands to a width of 12.07 inches (306.5
mm) for a UPS and an external battery
module. Align the stands approximately
10 inches (254 mm) apart. Have one or
more assistants help you place the UPS
on its side in the stands. Place the UPS
so that its control panel is on top and
facing outward.
Rotate the UPS's control panel to view
2
it easier while the UPS is tower mounted.
Insert a small screwdriver, or other tool,
in the slots on either side of the control
panel. Pop the panel out; rotate it; and
pop the panel back into place.
201102170 932611.indd 5
1
3
1 Power Module
1 Power Module
6.93" (176 mm)
6.93" (176 mm)
1
5
2
4
1 Power Module +
1 Battery Module
1 Power Module +
1 Battery Module
12.07" (306.5 mm)
12.07" (306.5 mm)
1
2
3/30/2011 10:22:11 AM