Positioning The Extraction Hood - Kemper MaxiFil Clean Instrucciones De Servicio

Ocultar thumbs Ver también para MaxiFil Clean:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 156
Connection socket for start-stop sensor (item 9)
A start/stop sensor can optionally be connected here. Its use means that
the extraction system will only operate during the pure welding time
(arcing time) plus the set run-on time. The start/stop sensor is
automatically detected by the product.

6.3 Positioning the extraction hood

The extraction arm or extraction hood is designed in such a way that it can
be adjusted and moved easily by hand. Once it has been positioned, the
extraction hood maintains its set position of its own accord. Furthermore,
both the extraction hood and the arm can be pivoted through 360° so that
almost any position can be set. It is important that the extraction hood is
always positioned properly in order to achieve adequate capture of the
welding fumes. The correct position is shown on the following image.
Position the extraction arm so that the extraction hood is located
approx. 25 cm diagonally above the weld.
The extraction hood must be positioned so that it safely captures the
welding fumes, taking into account the movement of welding fumes
caused by the heat and the extraction range.
Always move the extraction hood with respect to the weld position as
you advance.
1502827-03
Fig. 15: Positioning the extraction hood