WARNING
An incorrectly positioned extraction hood or too low an extraction
capacity do not ensure that air containing hazardous substances is
captured adequately by the extraction hood. This means hazardous
substances can enter the area where the operating personnel breathes
and cause severe damage to health.

6.4 Commissioning

WARNING
Danger due to faulty product condition.
The product must be fully installed before commissioning begins. All
doors must be closed and the necessary connections must have been
made.
1. Connect the power cable to the on-site mains connection.
2. Connect the power cable to the on-site air compressed air network.
3. Switch the product on using the pushbutton marked "0" and "I".
4. The fan starts and the green indicator lamp on the device switch signals
error-free operation of the product.
If there is a fault, please refer to the "Troubleshooting" chapter.