Kemper MaxiFil Clean Instrucciones De Servicio página 61

Ocultar thumbs Ver también para MaxiFil Clean:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 156
Item
Description
1
Device button (I/0) with power light
2
Information signal lamp
3
Regulator for run-on time in start/stop operation
4
Maintenance socket (for service staff only)
5
Signal horn
6
Pressure measurement opening (for service staff
only)
7
Pressure switch, cleaning (for service staff only)
8
Pressure switch, minimum volume flow (for service
staff only)
9
Connector socket for start-stop sensor
I/0 switch (item 1)
The product is switched on and off by pressing the switch.
The green indicator lamp of the switch indicates trouble-free operation
of the product or the readiness for operation when using an optional
start/stop sensor. The green signal lamp will turn off if there is an error
or malfunction. The product will switch off automatically.
Signal lamp (item 2)
The yellow signal lamp indicates a fault or an error in the product. These
faults are displayed using different blink codes for optical reference.
Signal lamp flashes evenly at regular intervals:
Product maintenance is due, inform service
Signal lamp flashes briefly twice in a row at regular intervals:
The motor protection switch has triggered, inform service
Signal lamp flashes briefly three times in a row at regular
intervals:
Incorrect rotating field, the fan is rotating in the wrong
direction.
To rectify this, an electrician must swap two phases in the CEE
connector plug.
Signal lamp flashes briefly 4x in a row at regular intervals:
1502827-03
Tab. 14: Operating elements
- 61 -
EN
Note

Publicidad

Tabla de contenido
loading

Tabla de contenido