ATTENTION
Risk of damage! Do not use detergents
containing silicone to clean.
– No outside help is required for carrying
out basic maintenance and cleaning.
– The appliance surface and the inside of
the container should be cleaned regu-
larly using a damp cloth.
WARNING
Risk due to dust hazardous to health. Al-
ways use disposal clothing and P2 or high-
er breath-safe masks while carrying out
maintenance tasks (such as changing fil-
ters).
Exchanging the flat pleated filter
Open filter door.
Take out the flat folded filter.
Dispose off the used flat-folded filter in
a dust-tight bag according to the statu-
tory provisions.
Remove the dirt that has accumulated
on the pure air side.
Insert new flat-folded filter.
Press the filter foam rim down onto the
edge.
Close the filter door, it must lock into
place.
Replacing the paper filter bag
Illustration
Release and remove the suction head.
Pull the paper filter bag out towards the
back.
Pull up the locking slide and tightly
close the paper filter bag upon removal.
Dispose of the used paper filter bag ac-
cording to the statutory provisions.
Fit new paper filter bag.
Insert and lock the suction head.
Replacing the disposal bag
Illustration
Release and remove the suction head.
Pull the disposal bag up.
Pull the opening of the disposal bag out
toward the back over the suction sup-
port and seal it tightly.
20
Tightly seal the disposal bag with clo-
sure strips underneath the opening.
Remove the disposal bag.
Dispose of the used disposal bag ac-
cording to the local provisions.
Attach the new disposal bag.
Place the disposal bag over the con-
tainer.
Insert and lock the suction head.
Cleaning the electrodes
Release and remove the suction head.
Clean the electrodes with a brush.
Insert and lock the suction head.
Troubleshooting
DANGER
First pull out the plug from the mains before
carrying out any tasks on the machine.
Note: In case of a failure (e.g. filter break-
age) the appliance must be turned off im-
mediately. The failure must be remedied
before the appliance is put into operation
again.
Suction turbine does not run
Check the receptacle and the fuse of
the power supply.
Check the power cable, the power plug,
the electrodes and the receptacle of the
device.
Turn on the appliance.
Suction turbine turns off
Empty the container.
Suction turbine does not start again
after the container has been
Turn off the appliance and wait for 5
seconds, turn it on again after 5 sec-
onds.
Clean the electrodes as well as the
space between the electrodes with a
brush.
– 6
EN
emptied