Connection

Connecting a drive to a braking unit and a braking resistor
Connecting two drives, both connected to a braking unit, to a single DC BUS
3 AC
L1
ATV71
U
Note: DC bus
It is possible to have drives of different ratings connected to one DC bus (with the recommendation that there is a maximum of 1 size
between ratings).
1757084 11/2009
3 AC
L1
L2
L3
ATV71
+
BU
BU
U
V
W
M
Power link
L2
L3
BU
+
BU
V
W
M
TH
+
PA
BU
PB
BU
Braking unit
Control link
Braking
resistor
TH
PA
BU
+
PB
BU
Braking unit
3 AC
L1
L2
L3
ATV71
BU
+
BU
U
V
W
M
Braking
resistor
PA
BU
+
PB
BU
Braking unit
TH
Braking
resistor