VDROO 32-200 process:
From model VDROO 32 and above, the pump is supplied with a fork shaped calibrated
separator that facilitates the motor coupling and replacement.
1. Remove the metallic coupling guards.
2. Untighten the bolts that hold the mechanical coupling.
3. Untighten the bolts that hold the motor in place and remove it.
4. Untighten the six screws that hold the seal into place (three on the shaft and three
on the top support). Extract the mechanic seal.
5. To install the new mechanic seal, insert it in the same position as the previous one.
6. Insert the three screws that hold the seal of the hydraulic pump head.
7. Tighten the screws that hold the mechanical seal of the pump shaft.
8. Lift the pump shaft and place the filler gauge below the seal collar.
9. Put the motor back into place and tighten the screws that secure the motor.
10. Position the mechanical coupling so that that there is the same gap on all the
sides (motor and hydraulic part).
11. Remove the filler gauge.
12. Place the metallic coupling guards and secure it by means of the side screws.
90

9. FREEZE PROTECTION

ATTENTION:
Pumps which are not in use during freezing periods should be drained to
avoid damage. Drain the pump by loosening the vent screw in the pump
head and removing the drain plug from the base.
DANGER:
Pay attention to the direction of the vent hole and make sure that the
water coming out of the pump does not cause injuries to people or any
damage to the motor or other components. In the case of hot-water
installations, pay special attention to the risk of injuries from scalding hot
water.
Do not tighten the vent screw and place the drain plug until the pumps is
to be used again.

10. TROUBLESHOOTING

DANGER:
Make sure that the power supply has been switched off and that it
cannot be accidentally switched on before removing the terminal box
cover and before removing/dismantling the pump.