Installation / Operation
13. Use insulated crimp type connectors.
14. Protect the electrical wires from sharp objects, hot sur-
faces, oil, and chemicals. Avoid kinking the wires.
Replace or repair damaged or worn wires immediately.
15. Do not touch an operating motor. Modern motors
can operate at high temperatures.
16. Do not handle the pump or pump motor, or change
wiring with wet hands or when standing on a wet or
damp surface, or in water.
Hazardous voltage. Can shock, burn or
kill. Do not walk on a wet area. Do not lift the pump
by the power cord.
INSTALLATION
1. Locate the pump as close to the water supply as
possible (the shorter the distance the better the pump
performance).
NOTICE: Do not secure the pump in a position with
the motor facing down. The motor is splash proof,
but not water proof.
Fire and explosion hazard. Can cause
severe injury, property damage or death. The motor is
not ignition proof. Do not use in explosive atmospheres.
2. Secure the pump on a hard surface.
3. Connect the outlet hose.
4. Prime the pump.
• Connect the inlet hose. Be sure all connections
are airtight.
• Fill the inlet hose with water and put the open
end of the hose in the water you wish to pump.
5. Connect the inlet hose. Be sure all connections are
air tight.
NOTICE: Do not allow the inlet hose to lie in dirt or
sand. This will cause rapid wear of the pump.
6. Be sure the discharge line is open and that the line
has no kinks or coils in it.
7. Connect the motor lead wires as indicated in Table I
and as shown in Figure 1.
NOTICE: In order for the pump to run in the proper
direction, the wires must be connected correctly.
8. Power Supply: Pump is designed for use with a 12
Volt DC battery. Operation requires a minimum 12
Volt power supply.
TABLE I – WIRING CONNECTIONS
Connect the ...
To ...
1. Red handled
Positive (+) battery terminal
battery clamp
2. Black handled
Negative (-) battery terminal
battery clamp
For parts or assistance, call Shur-Dri Customer Service at
Red Handled
Clamp to the
Positive Battery
Terminal
Figure - 1 Wiring Connections.
OPERATION
Risk of electric shock. Do not handle a
pump or pump motor with wet hands or when standing
on wet or damp surface, or in water.
Risk of Fire and Explosion. Can cause
severe injury, property damage or death. Do not use in
explosive atmospheres. Pump water only with this
pump.
1. The shaft seal depends on water for lubrication and
cooling. Do not operate the pump unless it is pump-
ing water. The seal will be damaged if the pump is
allowed to run dry. Fill the pump and inlet hose with
water before each use. Do this before starting the
pump.
NOTICE: DO NOT run this pump dry. Running this
pump dry will void the warranty.
2. The pump motor requires a fully charged 12V DC
battery for operation.
Risk of electric shock. Can burn or kill.
Before attempting to check why a unit has stopped
operating, disconnect the battery from the unit.
3. Make sure that all of the suction connections are air
tight. Most priming problems are due to air leaks in
the suction line.
4. If the pump does not pump water in one minute,
disconnect the pump from the battery and refer to
the troubleshooting section on Page 5.