Maintenance Programme; Cleaning - PEDRO GIL 454025 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Salvador Albert I Riera, 9 – Pol.Ind. Vallmorena
Tel. (34) 93 753 71 71 – Fax(34) 93 753 73 00
e-mail:
08339 VILASSAR DE DALT (Barcelona) España
9.1

MAINTENANCE PROGRAMME

-
• Oil Level
• Change Oil
• Lip Seal Change
• Inlet Filter Control
(Clean if the pressure falls bellow 50mbar)
-Replace
• Re-Tension Drive Belts
• V-Belts
-Check for wear and damage
-Replace
• Drive belt alignment
-Check aligment of pulleys of the motor and bower
• Pressure / vacuum releif Valve
-Control it operates correctly
• Check Valve
-Control leakage and wear
-Replace
• Check the Oil system hoses
(Replace them after 5 years)
• Flexible Connection
-Replace
• Noise and Vibration Control
• Electric Motor
(perform maintenance as indicated in the manufacturer's spec.)
• Inlet / Outlet panels in Enclosure
-Check and clean them
• General Inspection
-Authorised aftersales agent
Check the blower at the established intervals. Some intervals may vary, depending on the operating conditions of the
machine. In the event of doubt, contact PG Technical Service.

9.2- CLEANING

The blowers operate without the pistons coming into contact and with no contact between them and the body and end
covers. In addition, vertical media operations, in the event that the liquids carried are gases that could lead to condensation
or liquids being dragged continuously and evenly, the compression chamber always remains free from them, due to
gravity.