Hi-Class ACWG Instalación Uso Y Mantenimiento página 19

Tabla de contenido

Publicidad

IT
UJQP!EJ!BMMBSNF
01 / 01 / 2016
09 : 02
TANICA PIENA
APRIRE MOBILE
E
C
O
01 / 01 / 2016
09 : 02
VUOTARE TANICA
REINSERIRE TUBO
E
C
O
Interviene quando la tanica den-
tro il mobile è piena di acqua di
scarico.
01 / 01 / 2016
09 : 02
SANIFICAZIONE
ENTRO 15 GIORNI
E
C
O
01 / 01 / 2016
09 : 02
SANIFICAZIONE
NECESSARIA
E
C
O
Se è impostato, il "Calendario Sa-
nifi cazione" avverte 15gg prima
della scadenza fi no al termine.
TPMV[JPOF
Vuotare la tanica e riposizionarla
correttamente nella sue sede dentro
il mobiletto avendo cura di reinserire
correttamente il tubo dentro l'imboc-
co della tanica.
Contattare servizio di assistenza per
effettuare la Sanifi cazione.
Una volta effettuata la sanifi cazione
azzerare il "Contatore Giorni di Sa-
nifi cazione" infi ne spegnere e riac-
cendere la macchina.
EN
BMBSN!NFTTBHF
01 / 01 / 2016
09 : 02
NO WATER
E
C
O
On WG versions a safety system
stops the carbonation pump if it
runs for more than 4 minutes, and
also disables the operation of the
carbonated water solenoid valve.
CALL SERVICE
01 / 01 / 2016
09 : 02
PROBE ALARM
ICE BANK
E
C
O
Displayed when the temperature
probe is malfunctioning and:
• Temperature readings are in-
correct;
• Cooling cycles do not work
properly;
• If the temperature values are
outside the established limits.
CALL SERVICE
01 / 01 / 2016
09 : 02
PROBE ALARM
HOT TANK
E
C
O
Displayed when the temperature
probe is malfunctioning and:
• Temperature readings are in-
correct;
• A correct management of the
cooling cycles;
• If the temperature values are
outside the established limits.
CALL SERVICE
01 / 01 / 2016
09 : 02
ALARM COMPRESSOR
E
C
O
Advises that the compressor has
not managed to reach the set
temperature after 12 hours of
functioning.
CALL SERVICE
TPMVUJPO
MAKE SURE:
• that there is water in the mains;
• that the hydraulic circuit is prop-
erly connected;
• that the fi lter (if present) is not
clogged;
• that the level probe in the carbon-
ator is connected;
• that the stainless steel coil is not
frozen;
• that the pump is not blocked or
obstructed.
It will not be possible to draw car-
bonated water until the cause of the
problem has been removed.
Once the cause of the problem is
removed, switch the water cooler off
and on again to resume operation.
MAKE SURE:
• That there is electrical continuity
in the temperature sensor (use a
multimeter);
• That the temperature sensor is
electrically connected.
It will not be possible to draw cold
carbonated or still water until the
cause of the problem has been re-
moved; in addition, the compressor
will not work.
Once the cause of the problem is
removed, switch the water cooler off
and on again to resume operation.
MAKE SURE:
• That there is electrical continuity
in the temperature sensor (use a
multimeter);
• That the temperature sensor is
electrically connected.
Hot water cannot be dispensed
until the problem is resolved. Fur-
thermore, the heating function is
blocked.
Once the cause of the problem is
removed, switch the water cooler off
and on again to resume operation.
Contact the assistance service to
check the cause of the malfunction-
ing of the compressor:
• Make sure that no electrical wire
that feeds the compressor has
become detached;
• Make sure that there no gas leaks
in the refrigerant circuit or if the
compressor is defective.
Once the problem has been re-
solved, switch off and then switch on
the machine to eliminate the alarm
screen.
19

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Achwg

Tabla de contenido