Maintenance and care
Cleaning silencer (Check periodically)
1. Exhaust guide
2. Silencer cover
Check fuel system (Check before each use)
1. Fuel tank cap
Check spark plug (Check periodically)
a: 0.6 - 0.7 mm
Lubricating gear housing (Every 15 - 20 hours of operation)
1. Grease fitting
All manuals and user guides at all-guides.com
3. Two bolts
4. Silencer
20
1.
Remove the exhaust guide and silencer cover.
2.
Clean deposits from the silencer and the exhaust guide.
3.
Tighten two bolts.
4.
Reinstall the silencer cover and the exhaust guide.
After refuelling, make sure fuel does not leak or exude from
around fuel pipe, fuel grommet or fuel tank cap.
In case of fuel leakage or exudation there is a danger of fire.
Stop using the machine immediately and request your ECHO
DEALER to inspect or replace.
Check plug gap. Correct gap is 0.6 mm to 0.7 mm.
Inspect electrode for wear.
Inspect insulator for oil or other deposits.
Replace plug if needed and tighten to 15 N•m - 17 N•m (150
kgf•cm to 170 kgf•cm).
1.
Clean dirt from grease fitting.
2.
Hold the product firmly and carefully pump grease in fitting.
Do not force grease. Too much pressure will force grease
past seals and cause damage. Apply 1 - 2 pumps of
grease every 15 - 20 hours of operation.
NOTE
Use good quality lithium multi grease.