Changing The Oil - Dometic TEC40D Instrucciones De Uso

Ocultar thumbs Ver también para TEC40D:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 73
TEC40D
10.4

Changing the oil

!
CAUTION!
Hot oil can cause burns.
A
NOTICE!
Only dispose of used oil at a specialist recycling station and
observe the local laws for environmental protection.
You may use the following oil:
 Oil with the specifications:
– CCMC D4, D5, PD
– API CD, CE, CF, CG
– SHPD
 SAE grade oils:
– 5W-30
– 5W-40
– 100W
– 100W-30 (recommended)
– 10W-30
– 15W-30
– 30
– 40
 Oil with single grade oil viscosity:
Select the appropriate viscosity according to the average temperature
on-site.
Change the oil as follows (fig. 6, page 5):
➤ Allow the generator to run warm for three to five minutes so that the oil
can drain off faster and completely.
➤ Take the dipstick (1) out of the filler neck (2).
➤ Place a suitable receptacle (4) near the oil hose (5).
➤ Loosen the clamp (3).
➤ Take off the oil hose (5) and let the oil drain off into the receptacle (4).
➤ Put the oil hose (5) onto the hose-end fitting.
➤ Fasten the oil hose (5) with the clamp (3).