10.3

Finishing maintenance work

➤ Connect the generator to the positive terminal of the supply battery.
➤ Switch the generator to standby with the main switch (fig. 4 1, page 4).
➤ Close the generator flap.
10.4

Changing the oil

!
CAUTION!
Hot oil can cause burns.
A
NOTICE!
Only dispose of used oil at a specialist recycling station and observe the
local laws for environmental protection.
You may use the following oil:
• SAE 5W-30 grade oil (can be used at any temperature).
• Oil with single grade oil viscosity.
Select the appropriate viscosity according to the average temperature on-site.
Change the oil as follows:
➤ Allow the generator to run until warm so that the oil can drain off faster and
completely.
➤ Place a suitable receptacle under the drain plug (fig. 6 1, page 5).
➤ Remove the dipstick.
➤ Take out the drain plug (fig. 6 1, page 5).
✓ The oil drains off.
➤ Pour fresh oil into the filler neck.
The amount of oil is: 1.1 l.