Technical Data - REMS Multi-Push S Instrucciones De Servicio

Ocultar thumbs Ver también para Multi-Push S:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 63
eng
air of up to 1 MPa/10 bar/145 psi and in pressure tests with water of up to
1.8 MPa/18 bar/261 psi. So be very careful. Never let the power tool operate
unattended. Keep third parties away from the work area when working with the
electrical device.
work. Electrical devices can cause hazards which lead to material damage or
injury when left unattended.
This could cause water damage.
Damaged high-pressure hoses can burst and cause injury.
tool. This ensures that the safety of the device is maintained.
into the electrical device increases the risk of electric shock.
water into the electrical device increases the risk of electric shock.
alcohol, solvent, with the power tool. The fumes or liquids can ignite or explode.
The fumes or liquids can ignite or explode.
Protect the power tool against frost. The device could be damaged. Let the
power tool run empty for about 1 minute, if necessary, to drain off remaining water.
Never let the power tool operate unattended. Switch the power tool off at
Electrical devices can cause hazards which lead to material damage or injury
when left unattended.
The power tool could be damaged by overheating.
Date 2020-04-08". Installation of an older software version on REMS Multi-Push
S is not permitted and will lead to malfunctions. This could damage the power
tool/installation.
responsible person. Otherwise there is a risk of operating errors and injuries.
the power tool when they are over 16, when this is necessary for their training
and when they are supervised by a trained operative.
customer service workshop in case of damage.
cable cross-section. Use extension leads up to a length of 10 m with cable
cross-section 1.5 mm², from 10 – 30 m with cable cross-section 2.5 mm².
WARNING
WARNING
Danger with a medium degree of risk which could result in
death or severe injury (irreversible) if not heeded.
CAUTION
CAUTION
Danger with a low degree of risk which could result in minor
injury (reversible) if not heeded.
NOTICE
NOTICE
Material damage, no safety note! No danger of injury.
Read the operating manual before starting
Use eye protection
Use hand protection
Power tool complies with protection class I
Environmentally friendly disposal
CE conformity mark

1 Technical data

Use for the intended purpose
WARNING
WARNING
Only use the power tool for the purpose intended. Failure to do so can result in death
or severe injury.
REMS Multi-Push is intended for
Flushing of drinking water installations with water in accordance with EN
806-4:2010, according to Technical Rule – Worksheet DVGW W 557 (A) October
2012 "Cleaning and disinfection of drinking water installations" of the DVGW
disinfection and commissioning of drinking water installations" (August 2014)
20
There is a danger of accident.
r operation. Penetration of water
Penetration of
Apprentices may only use
Central Association for Sanitary, Heating, Air Conditioning (ZVSHK), Germany
Flushing of drinking water
in accordance with EN 806-4:2010, according to Technical
Rule – Worksheet DVGW W 557 (A) October 2012 "Cleaning and disinfection of
drinking water installations" of the DVGW German Gas and Water Association
of drinking water installations" (August 2014) Central Association for Sanitary,
surface heating systems.
Disinfection with disinfection unit REMS V-Jet TW: Disinfection of drinking
water installations in accordance with EN 806-4:2010, according to Technical
Rule – Worksheet DVGW W 557 (A) October 2012 "Cleaning and disinfection of
drinking water installations" of the DVGW German Gas and Water Association
of drinking water installations" (August 2014) of the Central Association for
Sanitary, Heating, Air Conditioning (ZVSHK), Germany and other pipe systems.
Use of active ingredient REMS Peroxi Color.
Cleaning and preservation with cleaning and preservation unit REMS V-Jet
H: Cleaning and preservation of radiators and area heating systems. Use of the
active ingredients REMS CleanH and REMS NoCor.
2011) of the German Central Association for Sanitary, Heating and Air Conditioning
(ZVSHK) and pressure and leak testing of other pipe systems and vessels (REMS
Multi-Push SL/SLW).
2011) of the German Central Association for Sanitary, Heating and Air Conditioning
(ZVSHK) and pressure and load testing of other pipe systems and vessels (REMS
Multi-Push SL/SLW).
accordance with EN 806-4:2010, Test Method A and for pressure and leak testing
of other pipe systems and vessels (REMS Multi-Push SLW).
German Central Association for Sanitary, Heating and Air Conditioning and pres-
sure and leak testing of other pipe systems and vessels (REMS Multi-Push SLW).
accordance with EN 806-4:2010, Test Method C and for pressure and leak testing
of other pipe systems and vessels (REMS Multi-Push SLW).
ance with EN 1775:2007, according to Technical Rule – Worksheet G 600 April
2018 (DVGW-TRGI 2018) "Technical Rules for Gas Installations" of the DVGW
German Gas and Water Association (REMS Multi-Push SL/SLW).
according to Technical Rule – Worksheet G 600 April 2018 (DVGW-TRGI 2018)
"Technical Rules for Gas Installations" of the DVGW German Gas and Water
Association (REMS Multi-Push SL/SLW).
(REMS Multi-Push SL/SLW),
All other uses are not for the intended purpose and are therefore prohibited.
Attention: Use for the intended purpose also includes consideration and
Attention: Use for the intended purpose also includes consideration and
Technical Rules for Drinking Water Installations
European standard EN 806-4:2010 "Technical Rules for Drinking Water Instal-
lations – Part 4: Installation"
Based on the currently valid European directive 98/83/EC "on the quality of water
installations inside buildings conveying water for human consumption – Part 4:
Installation" was adopted by the European Committee for Standardisation (CEN) on
the 23rd of February 2010 and had to receive the status of a national standard in
pressure testing of installations inside buildings for water for human consumption"
under 6.1 "Installations inside buildings must be subjected to pressure testing. This
can be done either with water or, if national regulations allow
if national regulations allow, oil-free, clean air with
low pressure or inert gases may be used. The possible risk from high gas or air
pressure in the system must be considered." However, the standard EN 806-4:2010
contains no test criteria at all for testing with air apart from this note.
Sub-sections to 6.1 offer 3 test methods A, B, C for hydrostatic pressure testing
depending on the material and size of the installed pipes The test methods A, B and
C differ in different test sequences, pressures and times.
eng
diators and
in accord-
in accord-
in
in in
in in
in accord-
in accordance with EN 1775:2007,

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Multi-push slMulti-push slw

Tabla de contenido