Kohler K-10673 Guía De Mantenimiento página 22

Ocultar thumbs Ver también para K-10673:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting (cont.)
Symptom
Probable
Cause
4. Sporadic
A. Wires are
flow.
pinched or
damaged.
B. Low
battery.
5. Water is
A. Vacuum
leaking
breaker is
from the
worn, or
vacuum
damaged.
breaker
connection
with the
valve.
6. Water
A. Arm to
leaking
control
from the
stop seal is
valve inlet.
worn or
damaged.
1108709-5-C
All manuals and user guides at all-guides.com
Recommended Action
• Remove the valve cover.
• If wires are cut or damaged,
order new solenoid or sensor
assembly.
• Verify that both wires are
tucked inside the cover before
reassembling.
• Follow the directions of
"Replace the Batteries" section
in this guide.
• Turn off the water supply.
• Purge the valve.
• Disconnect the valve from the
vacuum breaker assembly.
• Replace rubber vacuum
breaker.
• Reassemble the valve to the
vacuum breaker assembly.
• Turn off the water supply.
• Purge the valve.
• Disconnect the valve from the
control stop.
• Inspect the O-ring seal for the
control stop to inlet connection.
• Clean any debris from area.
• If the O-ring is cut or torn,
order a replacement.
• Reassemble the unit, taking
care to tighten the nut onto the
control stop.
22
Kohler Co.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

K-10674K-10677

Tabla de contenido