Trouble shooting
If
Try this
Two orange lights
• Change batteries. Only use 1.5 V AA (LR6) lithium or
appear every minute
alkaline batteries.
A green light appears
• Check the telephone transmitter's and the receiver's
on the transmitter
batteries and connections.
but the receiver is not
• Move the receiver closer to the telephone transmitter.
activated
• Check that the telephone transmitter and the receiver
is set to the same radio key. For more information, see
Changing the radio key in the Installer's guide.
No green light appears
• Press both test buttons simultaneously.
on the transmitter
• If a green light appears, check all connections.
when the phone rings
• If no green light appears, change batteries. Only use
or when the accessory
1.5 V AA (LR6) lithium or alkaline batteries.
is activated
25
If
Try this
No green light appears
• Change batteries. Only use 1.5 V AA (LR6) lithium
on the transmitter when I
or alkaline batteries. If the green light still doesn't
press the test button(s)
appear, contact your retailer for information
about obtaining warranty service.
The receiver is activated
• There is probably another Visit system installed
for no reason
nearby that triggers your system. Change the
radio key on all units, see Changing the radio
key in the Installer's guide.
EN
26