Trigger Input - Bellman & Symfon BE1431 Manual Del Usuario

Ocultar thumbs Ver también para BE1431:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 16

Trigger input

You can use both stereo and mono plugs. The 3.5 mm input is located on the
top right side and the 2.5 mm input under the lid.
Mono
Trig is made by closing the two connectors
Stereo
Trig is made by:
1 Closing the outer and middle connector or closing the
outer and inner connector
2 Applying 2-30VDC or 3-24VAC 5-150Hz between the
middle and inner connector
Please note
When you use the 2.5 mm ext trig, the event must last for more than 2 seconds
119
Installer's Guide
Technical information
Power supply
Battery power: 2 x 1.5 V AA (LR6) lithium or alkaline
Power consumption
Active < 70 mA, Idle position < 15 μA
Operating time
Alkaline ~ 5 years, Lithium ~ 10 years
Activation
Via test buttons, RJ11 input to analogue telephone network (26 -
120 V RMS, 15 - 100 Hz), 2.5 mm ext trig, 3.5 mm ext trig
Radio frequency
314.91 MHz, 433.92 MHz or 868.3 MHz depending on region
Coverage
50 – 250m (55 – 273yd) depending on radio frequency. Coverage is
reduced by walls, large objects and other radio transmitters.
Number of radio keys
64 as standard. Up to 256 with optional software.
Accessories
BE9250 Mobile phone sensor, BE9026 Contact mat
BE9023 Magnetic switch and BE9253 External trig cable
Additional information
Operating temperature
0° – 35° C, 32° – 95° F
Transport and storage temp. -10° – 50° C, 14° – 122° F
Relative humidity
15% – 90% (non condensing)
Maintenance and cleaning
Maintenance free. Clean with a dry cloth. Don't use household
cleaners, aerosol sprays, solvents, alcohol, ammonia, or abrasives.
Warranty and service
If the product appears to be damaged or doesn't function properly,
follow the advice in this booklet. If it still doesn't function properly,
contact your retailer for info about obtaining warranty service.
Installer's Guide