Maintenance; Warranty - SPARKY PROFESSIONAL K 3260 Instrucciones De Uso Originales

Ocultar thumbs Ver también para PROFESSIONAL K 3260:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34

Maintenance

WARNING: Always ensure that the tool is
switched off and unplugged before attempting to perform
inspection or maintenance.
The power tool is delivered with proper amount of lubri-
cant. Do not add lubricant to a newly purchased breaker.
Check the level of lubricant and replace it every 6 months
after initial operation. These activities shall be performed
Preventive care will prolong the life of your power tool.
If the impact energy begins to decrease or the bit shank
is dry and unlubricated during operation, contact author-
ized SPARKY service centre to check lubricant level
and/or quality of fast-wearing parts.
can be achieved only with well-sharpened accessories
for demolition and chiselling. Operating with a dull tool
When signs of abrasion are noted, it is necessary to
sharpen or replace the tool immediately.
Regularly inspect all fasteners and ensure they are
properly tightened. Should any of the screws be loose,
retighten it immediately to avoid hazards.
After continuous operation the retainer may wear out.
Ensure that the tool shank is securely tightened. In case
of wear or damage call immediately the local SPARKY
service centre for warranty and post-warranty mainte-
nance.
To prevent motor damage never allow contact of motor
windings with water or oil.
(Fig. 6)
This power tool is equipped with auto-stop brushes.
When the carbon brushes are worn out, the machine au-
tomatically switches off. Both brushes must be replaced
after 100-120h of operation at SPARKY authorised ser-
vice centre. This power tool is designed to ensure fast
and easy brush replacement even by the customer. We
recommend though during the warranty period to per-
form this operation in the authorised SPARKY service
centres.
To replace brushes dismantle the parts marked by the
sequence of their removal:
1. Inner hex bolt M6x20
3. Brush holder cap
4. Carbon brush set
To assemble perform the above described procedures
in reverse order.
Original instructions
After replacing the brushes make sure the
screws are securely tightened.
CLEANING
Always clean the ventilation slots and the tool holder af-
ter operation carefully with a dry brush.
Exterior plastic parts may be cleaned with a damp cloth
and mild detergent.
WARNING: Although exterior plastic parts
are highly solvent resistant, never use solvents!
To assure product safety and reliability,
repairs, maintenance and adjustment should be per-
service organisations, always using genuine replace-
ment parts.

Warranty

The guarantee period for SPARKY power tools is deter-
mined in the guarantee card.
dling will be excluded from the guarantee.
defects in workmanship will be corrected free of charge
through replacement or repair.
The complaints for defective SPARKY power tools will
be recognized if the machine is sent back to the dealer
or is presented to the authorised warranty service centre
undismantled, in its initial condition.
Notes
Carefully read the entire original instructions before us-
ing this product.
The manufacturer reserves the right to make changes
tions without prior notice.
-
-
-
7
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido