Ofrecido por www.electromanuales.com
Symptom
Temperature display shows
a square or a letter.
Warning tone sounds, red
warning indicator light and
temperature display are
flashing.
Interior illumination does
not function.
Water on the floor or on
storage shelves.
Heavy build up of frost,
possibly also on the door
seal.
The compressor does not
start immediately after
changing the temperature
setting.
Noise
If after the above checks there is still a fault, call your local AEG Service
Force Centre.
818 41 56-00/1
Possible Cause
There is a function fault.
Temperature warning.
Light bulb is defective.
Important: The interior
lighting switches off auto-
matically after 7 minutes.
Water drain hole is
blocked.
Door seal is not air tight
(possibly after changing
over the hinges).
This is normal, no error has
occurred.
Appliance is not level.
Fan running.
What to do if ...
Solution
Please inform customer
service. Do not open the
doors of the appliance
again.
Please check in "Control
and Information System"
section.
Please refer to "Replacing
the Light Bulb" section.
See the "Maintenance and
Cleaning" section.
Carefully warm the leak-
ing sections of the door
seal with a hair dryer (not
hotter than approx. 50 °C).
At the same time shape the
warmed door seal by hand
such that it sits correctly.
The compressor starts after
a period of time.
Readjust the front levelling
feet.
Refer to Normal Operating
Sounds
Normal operating noise.
The fan provides constant
temperature distribution in
the appliance.
43