Model(s) : AE140JXYDGH
B
Air-to-water heat pump : yes
C
Water-to-water heat pump : no
D
Brine-to-water heat pump : no
E
Low-temperature heat pump : no
F
Equipped with a supplementary heater : no
G
Heat pump combination heater : no
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low-temperature heat pump,
H
parameters shall be declared for low-temperature application.
I
Parameters shall be declared for average climate conditions.
Item
(J)
N
Rated heat output(
*)
Declared capacity for heating for part load at indoor temperature 20 °C and
Q
outdoor temperature T j
Tj = -7 °C
Tj = +2 °C
-
Tj = +7 °C
Tj = +12 °C
T
Tj = bivalent temperature
U
Tj = operation limit temperature
For air-to-water heat pumps
V
Tj = -15 °C (if TOL < -20 °C)
W
Bivalent temperature
Y
Cycling interval capacity for heating
AB
Degradation co-efficient(
**)
AD
Power consumption in modes other than active mode
AF
Off mode
AG
Thermostat-off mode
AH
Standby mode
AI
Crankcase heater mode
AK
Other items
AL
Capacity control
Sound power level, indoors/
AP
outdoors
AQ
Emissions of nitrogen oxides
AS
For heat pump combination heater
AT
Declared load profile
AV
Daily electricity comsumption
AX
Contact details
(*)
For heat pump space heaters and heat pump combination heaters, the rated that output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a
AY
supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).
(**)
AZ
If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0.9.
BA
1)
Precautions as described in the installation/user manual must be taken when assembling, installing and maintaining this product.
2)
BB
If you are a professional looking for information on non-destructive disassembly and dismantling, please send an email to: erims.sec@samsung.com
Symbol
(K)
Value
(L)
Unit
(M)
Prated
(o)
9
kW
Pdh
7.5
kW
Pdh
4.6
kW
Pdh
2.9
kW
Pdh
4.0
kW
Pdh
7.5
kW
Pdh
8.5
kW
Pdh
-
kW
Tbiv
-7
°C
Pcych
-
kW
Cdh
0.9
-
P
0.008
kW
OFF
P
0.021
kW
TO
P
0.021
kW
SB
P
0.000
kW
CK
variable
(AM)
L
-/65
dB
WA
NOx
-
mg/kWh
-
Q
-
kWh
elec
http://www.samsung.com
Item
(J)
Seasonal space heating energy
P
efficiency
Declared coefficient of performance or primary energy ratio for part load at indoor
R
temperature 20 °C and outdoor temperature T j
Tj = -7 °C
Tj = +2 °C
-
Tj = +7 °C
Tj = +12 °C
T
Tj = bivalent temperature
U
Tj = operation limit temperature
For air-to-water heat pumps
V
Tj = -15 °C (if TOL < -20 °C)
For air-to-water heat pumps:
X
Operation limit temperature
Z
Cycling interval efficiency
Heating water operating limit
AC
temperature
AE
Supplementary heater
N
Rated heat output(
*)
AJ
Type of energy input
AK
Other items
For air-to-water heat pumps :
AN
Rated air flow rate, outdoors
For water-/brine-to-water heat
AR
pumps: Rated brine or water flow
rate, outdoor heat exchanger
AS
For heat pump combination heater
AU
Water heating energy efficiency
AW
Daily fuel consumption
Symbol
(K)
Value
(L)
Unit
(M)
η
112
%
s
(S)
COPd
1.77
-
(S)
COPd
2.78
-
COPd
(S)
3.51
-
COPd
(S)
6.54
-
COPd
(S)
1.77
-
(S)
COPd
1.53
-
(S)
COPd
-
-
TOL
-10
°C
COPcyc
(AA)
-
-
WTOL
-
°C
Psup
-
kW
-
6480
m
3
/h
(AO)
-
-
m
3
/h
(AO)
η
-
%
wh
Q
-
kWh
fuel
53