7. TO START WEIGHING
1. Weighing mode
A. Place the scale on a solid
and flat surface.
B. Place bowl (if used) on
the scale before turning on
the scale.
C. Press
to turn on the
scale.
D. Wait until LCD shows O to
start weighing. Press
to convert to weight mode if
needed.
E. Load weighing object on to
start weighing, LCD will show
the weight reading.
F. lf the weighing object is
water or milk, press
button to choose volume
mode and view the volume of
weighing object.
2. Volume indication mode
A. Place the scale on a
solid and flat surface.
B. Press
to turn on
the scale.
C. Wait until LCD shows O,
and press
button to
choose "Water" or "Milk"
mode.
D. Put a liquid container
onto the scale platform.
E. Press
button to
reset LCD to O
F. Pour liquid (water or
milk) into the container,
LCD shows the volume of
the liquid.
G. Press
button to
choose"Weight" mode and
view the weight of liquid.
USER MANUAL GLASS KS
8. "ZERO" OR "TARE" FUNCTION
To weigh different loads consecutively without removing loads from
the scale. Put first Load on the scale, get weight reading. Press
button to reset the LCD reading to O befare adding next load.
You can repeat this operation.
Condition 1: "ZERO" function
When total sum of all loads on scale ≤4% of scale's max.
weight capacity. (4%=80g when capacity is 2000g; 200g
when capacity is 5000g)
LCD will show -- -- or 0g each time
means not stable, please wait for a moment. 0g and meanwhile
an icon
on the left of LCD mean ZERO function is active.
Max.weight capacity remains unchanged.
Condition 2: "TARE" function
When total sum of all loads on scale > 4% of scale's max.
weight capacity. (4%=80g when capacity is 2000g; 200g
when capacity is 5000g)
LCD will show ---- or 0g each time
means not stable, please wait for a moment. 0g and meanwhile
an icon
on upper left corner of LCD mean TARE function is
active. Max. Weight capacity is reduced by total weight of all
loads.
Under this condition:
By pressing
, you can see the total weight of all loads on the
scale. lf you want to weigh more loads,just press
LCD reading to O again.
EN
EN
is pressed. -----
is pressed. -----
to reset