If the device does not work properly, please check the following steps:
-
Check if the manual was followed precisely and correctly
-
Check the following table for possible reasons
-
Check if all fuses are working
Problem
There is water underneath the
device
The mixing chamber/blades are
not clean after the automatic
self-cleaning program
The beverage tastes sandy
The mixing result is chunky
Error codes
Error code
Problem
E05
The motor is overloaded due
to too many ingredients
E06
The temperature sensors are
sticky or there are too many
ingredient
E07
The voltage is lower than 160
V or exceeds 260V
E08
Signal defect
E09
E10
The discharge hose is jammed
E11
The temperature sensor is
defective or damaged
E12
E13
The pass-through sensor is
defective or damaged
E14
Electrical fault
E15
The heating unit of the mixing
chamber is defective or
damaged
Solution
Make sure that the water and collection containers
are closed and that the collection container had not
spilled over.
Add a drop of detergent and select the intensive
cleaning mode
Gently wipe off by hand with a damp cloth
Reduce the quantity of ingredients used to prepare
your drink
Soak the ingredients before processing
Soak the ingredients and/or chop them before
preparation
Filter out any chunks using a sieve
Replace the blades
Solution
Reduce the amount of ingredients and
clean the machine
Reduce the amount of ingredient and
clean the sensors inside of the mixing
chamber
Please contact customer services
Please clean
Please contact customer services

Publicidad