Storage/Winter Protection; Malfunction Remedy; Technical Data - Oase SwimSkim 25 Instrucciones De Uso

Ocultar thumbs Ver también para SwimSkim 25:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34

Storage/winter protection

The unit is not frost-proof and has to be removed and put into storage if minus temperatures
are expected.
How to correctly store the unit:
 Thoroughly clean the unit.
 Check the unit for damage and replace damaged components.
 Store the pump submerged and in a frost-free environment.
 Protect electrical connections from moisture and dirt.

Malfunction remedy

Malfunction
The integrated pump is not run-
ning
The pump capacity is insufficient
The aeration is not working
The integrated pump shuts down
after a short running period

Technical data

Unit data
SwimSkim
Power connection voltage
Power frequency
Power consumption
Max. pump flow rate
Max. air flow rate, aerator
Filter volume
Suitable for max. pond surface
Length of power cable
Dimensions
Weight
16
Possible cause
No supply voltage
The impeller unit is blocked
The filter basket / foam filter is
soiled
The injector is clogged
The air hose between the float and
the injector is kinked or discon-
nected
The water temperature is too high Adhere to the maximum water
V AC
Hz
W
l/h
l/h
gal
m
Length
mm
Width
mm
Height
mm
kg
Remedy
Check the supply voltage
Clean
Clean
Clean
 Securely fasten the air hose
 Avoid kinking the air hose
temperature of + 35 °C
The pump will automatically start
up again after cooling down
25
220 ... 240
50
40.0
2500
300
0.9
25.0
10.0
332
297
263
2.68

Publicidad

Tabla de contenido
loading

Tabla de contenido