Operation

WARNING: Risk of electric shock. Do not handle a pump or pump motor with wet hands or when standing in a wet or damp surface, or in
water.
WARNING: Risk of Fire and Explosion. Can cause severe injury, property damage or death. Do not use in explosive atmospheres. Pump
water only with this pump.
1.
The shaft seal and impeller depend on water for lubrication and cooling. Do not operate the pump unless it is pumping water. The seal
will be damaged if the pump is allowed to run dry. Fill the pump inlet with water before each use. Do this before starting the pump.
NOTE: DO NOT run this pump dry. Running this pump dry will void the warranty.
2.
The pump motor requires a fully charged 12V DC battery for operation.
WARNING: Risk of electric shock. Can burn or kill. Before attempting to check why a unit has stopped operating, disconnect the pump
from the battery.
3.
Water should be pumping in 30 seconds or less. If not, make sure that all of the suction connections are air tight. Most priming
problems are due to air leaks in the suction line. Refill the pump inlet and repeat the process. If your pump does not prime on the
second try, disconnect the pump from the battery and refer to Troubleshooting.
NOTE: The motor must have air circulation around it for proper cooling. This pump will lift water 6 ft. Trying to lift water more than 6 ft.
can cause the motor to run hot.
4.
Disconnect the pump from the battery before all the water is completely gone. Do not run the pump dry!